EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. ENย ISOย 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
๐ฉ๐ช
DIN EN ISO 17640
๐ฌ๐ง
BS EN ISO 17640
๐ซ๐ท
NF EN ISO 17640
๐ฎ๐น
UNI EN ISO 17640
๐ช๐ธ
UNE EN ISO 17640
๐ณ๐ฑ
NEN EN ISO 17640
๐ฉ๐ช
DIN EN ISO 16810
๐ฌ๐ง
BS EN ISO 16810
๐ซ๐ท
NF EN ISO 16810
๐ฎ๐น
UNI EN ISO 16810
๐ช๐ธ
UNE EN ISO 16810
๐ณ๐ฑ
NEN EN ISO 16810
1,780
Accredited labs
17
Countries
Showing 1โ25 of 175 labs
A.U.E.M.
Active
ASTM E8/E 8M
DIN EN 10002-1
ASTM E 21
DIN EN 10002-5
DIN EN ISO 6892-2
+ 3 more
A2E ENVIRONNEMENT
Active
DIN EN 27888
DIN EN ISO 10523
DIN EN ISO 7393-2
NF X 31-615 (Uniquement
A2M INDUSTRIE
Active
(BS EN ISO 6892-1: 2019)
DIN EN 10002-1
ISO 6892-1 -2009
ASTM E8/E 8M
ISO 6892-1 -2016
+ 3 more
AC Environnement
Active
NF ISO 21438-3
NF X 43-269
NF ISO 21438-1
DIN EN ISO 16017-2
NF X 43-259
+ 3 more
ACEPE
Active
NF X 43-269
NF X 43-269 โ
NF X 43-050
NF ISO 22262-1 (parties utiles
ISO 16000-7
ACM PHARMA
Active
DIN EN 17126
DIN EN 13624
DIN EN 13727
DIN EN ISO 11930
DIN EN 14476
+ 3 more
AD-LAB - Brussieu
Active
NF X 43-269
NF X 43-050
NF X43-269 โ Annexe
NF X43-050 (parties utiles de la norme)
NF X43-050 (useful parts of the standard
+ 3 more
ADOUR BIO CONSEIL - A.BIO.C.
Active
0.95) based on BS ISO 21527-2:2008
DIN EN ISO 6888-2
DIN ISO 16649-2
DIN EN ISO 6888-3
DIN ISO 11665-4
+ 3 more
ADRIA
Active
DIN EN ISO 21528-1
DIN EN ISO 21528-2
0.95) based on BS ISO 21527-2:2008
DIN EN ISO 6888-2
DIN ISO 16649-2
+ 3 more
AEROLAB
Active
NF EN 12469 Annexe H pour PSM
NF X 44-201 (Octobre 1984) pour PSM
NF EN 12469 Annexe G
NF X 44-201
DIN EN 12469
+ 3 more
ALS
Active
NF X 43-269
NF X43-050 (parties utiles de
ISO 22262-1
NF X 43-257
NF X 43-050
+ 1 more
ALS France
Active
DIN EN 14902
DIN ISO 16000-3
DIN EN ISO 16017-1
DIN EN ISO 16017-2
DIN ISO 16000-4
+ 3 more
ALS France โ Site de Paris
Active
NF T 90-412
0.95) based on BS ISO 21527-2:2008
DIN EN ISO 6888-2
DIN EN ISO 16649-3
DIN EN ISO 6888-3
+ 3 more
AN DIAG
Active
NF X 43-269
NF X 43-269 - Annexe K
NF X43-050 (parties utiles de
ISO 22262-1
NF X 43-050
+ 1 more
APAVE EXPLOITATION FRANCE
Active
DIN EN 14385
ETSI EN 301 489-1 V2.2.3 2019-11
NF X43-551
IS EN 1948-1:2006 2006
DIN EN 14789
+ 3 more
AQUANALYSE Laboratoire
Active
NF T 90-412
DIN EN ISO 7899-1
DIN EN ISO 10304-1
DIN EN 12880
ISO 5815-1
+ 3 more
NF S92-501 (mars
ASTM E8/E 8M
DIN EN 10002-1
DIN EN 10002-5
DIN EN ISO 6892-2
DIN EN ISO 643
+ 3 more
AVEYRON LABO
Active
DIN EN ISO 14403-2
NF V 04-407
NF T 90-412
DIN EN ISO 7899-1
DIN EN ISO 10304-1
+ 3 more
No matching labs found.