EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
🇪🇸
UNE EN ISO 16810
🇳🇱
NEN EN ISO 16810
1,548
Accredited labs
15
Countries
Showing 351–375 of 1,548 labs
Diagenom
Active
Chromosomensatz (angeboren)
Chromosomensatz (erworben)
Adrenogenitales Syndrom
Angelman-Syndrom (15q11-Region, UBE3A)
Mikrodeletionen; AZFa-c)
+ 3 more
Diagnos MVZ
Active
HbA1c
Differentialblutbild, maschinell
Retikulozyten, maschinell
Kleines Blutbild
Thrombozyten
+ 3 more
Diehl Metering
Active
Volumen strömender 0,0005 m
− Durchfluss von Flüssigkeiten
0,025 m
Wasserzähler und 0,001 m
Durchflusssensoren
+ 3 more
BS EN ISO 17781:2017 (Section 5.2)
ASTM E 415 21
#ISO 10370
ASTM E45-25
ASTM A 262-15
+ 3 more
ISO 22196
DIN EN 1040
DIN EN IEC 60601-2-75
DIN EN 14347
DIN EN 13624
+ 3 more
Absolutdruck p *
Vickers hardness test (ISO 6507)
Flüssigkeitsvolumen *
variablem Volumen
aufnehmern sowie
+ 3 more
Sommer Werkstoffprüfservice
Active
DIN EN 10045-1
DIN EN ISO 6506-1
DIN EN ISO 6507-1
DIN EN ISO 6508-1
DIN EN ISO 6892-2
+ 3 more
Staber & Kollegen
Active
Blutbild groß
Thrombozyten
Urinsediment
Natrium
Kalium
+ 3 more
Aminosäureprofil
Guanidinoacetat
Kreatin
Hämoglobinprofil
Nitisinon (NTBC), Succinylaceton
+ 3 more
Dreifeld
Active
DIN EN ISO 5579
DIN EN 12681-1
DIN EN ISO 17636-1
DIN EN 14784-1
DIN EN ISO 16810
+ 3 more
Druck *
Negativer und
positiver Überdruck -0,01 bar
Positiver Überdruck p e
> 0,015 bar
+ 3 more
Duravit
Active
*6095991, BAG3 [OMIM *6038831
(-13910T>C) rs4988235
- PiM rs6647, PiZ rs28929474, rs17580
DIN EN 997
DIN EN 13407
+ 3 more
VDE 0468-2-1
VDE 0468-2-2
VDE 0468-2-6
DIN EN IEC 60068-2-11
DIN EN IEC 60068-2-13
+ 3 more
optische 0 mm
Werkzeugeinstell- und
/ Messgeräte
verwendete Abkürzungen:
EC-works
Active
DIN 25435-6
DIN 54018-1
DIN 54018-2
DIN EN 1971-1
DIN EN 1971-2
+ 3 more
ECOPOINT SRL
Active
ISO 5667-5
DIN EN 12457-2
BS EN 15662
DIN EN ISO 6888-1
ISO 19250
+ 3 more
ECOPRISMA SRL
Active
DIN EN 12457-2
DIN EN ISO 6888-1
ISO 750
DIN EN ISO 10304-1
ISO 15587-1
+ 3 more
DIN 40633-2
DIN 40633-3
DIN 53482
DIN 72551-100
DIN 72551-6
+ 3 more
DIN EN 12390-6
DIN EN 12504-4
DIN EN 933-1
NF P 15-435
NF P 18-459
+ 3 more
and Appx. 3 of HSG 227 (2004))
in Appendix 5 of HSG 227 (2004)
guides HSG 264 (2012) and
(HSG 264, 2012)
ELLAB
Active
Taupunkttemperatur
Widerstandssensor
–100 °C bis
> 140 °C bis
> 240 °C bis
+ 3 more
EMCCons RASEK
Active
- Gleichspannung
> 0,12 V
Vorverstärker > 1,2 V
> 12 V
> 120 V
+ 3 more
200 kg/h ≤ m ≤ 60000 kg/h
200 l/h ≤ Q ≤ 60000 l/h
200 kg/h ≤ m ≤ 30000 kg/h
200 l/h ≤ Q ≤ 30000 l/h
700 Pa ≤ P ≤ 2 MPa
+ 3 more
No matching labs found.