ISO 9614-1:2023

Sound Power — Intensity Method (Discrete Points)

This test uses a sound intensity probe to measure acoustic intensity at discrete points on a measurement surface, allowing determination of sound power levels without requiring a fully anechoic environment. The intensity-based approach is effective for characterizing noise sources in semi-reverberant or field conditions where traditional pressure-based methods are unreliable. It provides directional acoustic information and is valuable for source localization and acoustic modification assessment. Accreditation ensures proper probe calibration, measurement procedures, and data processing are maintained to standards.

What it measures

  • Sound intensity magnitude and direction (vector)
  • Sound power level by surface integration
  • A-weighted and frequency-weighted acoustic power
  • Sound radiation patterns from complex sources
🇩🇪 DIN EN ISO 9614-2 🇬🇧 BS EN ISO 9614-2 🇫🇷 NF EN ISO 9614-2 🇮🇹 UNI EN ISO 9614-2 🇪🇸 UNE EN ISO 9614-2 🇳🇱 NEN EN ISO 9614-2 🇩🇪 DIN EN ISO 3744 🇬🇧 BS EN ISO 3744 🇫🇷 NF EN ISO 3744 🇮🇹 UNI EN ISO 3744 🇪🇸 UNE EN ISO 3744 🇳🇱 NEN EN ISO 3744
1,670 Accredited labs
18 Countries

Showing 751–775 of 1,670 labs

DAkkS D-ML-13295-04-00 München, DE
Thromboplastinzeit) Thrombozytenfunktion 10-OH-Carbazepin 5-Hydroxyindolessigsäure (5-HIES) + 3 more
View Profile
DAkkS D-ML-13295-04-01 München, DE
Lamotrigin AFP HbA1c CA 125 AMH + 3 more
View Profile
DAkkS D-ML-13295-01-01 München, DE
Kleines Blutbild Differentialblutbild maschinell C-reaktives Protein (CRP) Differentialblutbild manuell Urinstatus + 3 more
View Profile
DAkkS D-ML-13295-03-00 München, DE
17-OH-Progesteron ACTH Androstendion Aldosteron Anti-TG Antikörper + 3 more
View Profile
DAkkS D-ML-13421-01-00 Ludwigshafen, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu CDT Ampicilin Cefepim + 3 more
View Profile
DAkkS D-ML-13136-01-01 Augsburg, DE
Rhythmusstörungen (ABCC9, AKAP9, ANK2,TT MSH2, MSH6, MUTYH, PMS2, PTEN, RAD51C, R Familiärer Brust- und Eierstockkrebs MSH2, MSH6, EPCAM ); SNV, CNV Birt-Hogg-Dubé-Syndrom (FLCN + 3 more
View Profile
DAkkS D-ML-13400-01-00 Groß Grönau, DE
AMA M2-3E IgG Anti-CCP (Cyclische Citrullin Antikörper) IgG Anti-dsDNS-NCX IgG Anti- Transglutaminase + 3 more
View Profile
DAkkS D-K-17518-01-01 Remscheid, DE
abweichungen Metrosoft CM und Messvolumen Metrosoft QUARTIS, mit einer Software der Fa. WENZEL Raumdiagonale Metromec Chur, CH von ≤ 4666 mm
View Profile
DAkkS D-K-15098-01-01 Leonberg, DE
Software von WENZEL einer Raumdiagonalen Messprojektoren einer Raumdiagonalen Koordinatenmessgeräte geräte mit einem Messmikroskope ≤ 600 mm Auswertesoftware Messvolumen mit + 2 more
View Profile
DAkkS D-K-15077-01-00 Aschaffenburg, DE
Parallelendmaße 0,5 mm bis DIN EN ISO 3650:1999 Parallelendmaße aus 0,5 mm bis Keramik oder Wolframkarbid nach + 3 more
View Profile
DAkkS D-K-22877-01-01 Eschweiler, DE
(ein- und mehrgängige zylindrische Außen- und geradlinigen Flanken und symmetrischem Profil sowie positiven Flankenwinkeln) + 3 more
View Profile
UKAS 23015 Mansfield, GB
and Appendix 3 of HSG 227 (2004)) Appendix 5 of HSG 227 (2004))
View Profile
DAkkS D-PL-22819-01-00 Lüdenscheid, DE
DIN 40050-9 IEC 60068-2-2 IEC 60068-2-6 DIN EN IEC 60068-2-13 DIN EN 60068-2-14 + 3 more
View Profile
UKAS 7736 Chelmsford, GB
(HSG 248) – 2021 (PCM) based on HSG 248 SAS 02 based on HSG 248
View Profile

Kovia

Active
UKAS 9942 Royal William Yard, GB
Appendix 5 of HSG 227 (2004)) HSG 227 (2004) HSG 264 (2012) and Appendix 3 of
View Profile
DAkkS D-ML-13173-01-00 Bad Oeynhausen, DE
Thrombozytenfunktion Amiodaron/Desethylamiodaron Cotinin Cyclosporin A Everolimus + 3 more
View Profile
DAkkS D-ML-21357-01-00 Heppenheim, DE
Albumin Alkohol ALP Anti-Faktor Xa (Fragmin) AT3 + 3 more
View Profile
DAkkS D-PL-19181-01-00 Winnenden, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN EN 13487 DIN 45635-46 + 2 more
View Profile
DAkkS D-K-15009-01-01 Leipzig, DE
Eindringkörper für 75° Sound system equipment — speech transmis Länge der Schnittlinien * Vergrößerungsnormale Abflachung bis 300 + 3 more
View Profile
DAkkS D-K-15082-01-00 Hamburg, DE
Durchfluss von Gasen 17 mL/s transferstandards Strömungswiderstand 5 mL/min 15,0 mL/min Laminar Flow Elemente 17 mL/min + 3 more
View Profile
DAkkS D-PL-22893-01-00 Rheine, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN EN 61400-11 ISO 9613-2
View Profile
DAkkS D-K-17059-02-01 Dresden, DE
Messschieber für Außen-, 0 mm Innen- und Tiefenmaße > 300 mm Tiefenmessschieber 0 mm Höhenmessschieber 0 mm + 3 more
View Profile

LAB (UK)

Active
UKAS 0671 Basildon, GB
(HSG 248) – 2021 (PCM) based on HSG 248 MAAM 05 based on HSG 248 (HSG 264, 2012)
View Profile

LABACUSTIC

Active
ENAC LE1438 Vall d Uixó, ES
UNE-EN ISO 140-5 UNE-EN ISO 16283-3 UNE-EN ISO 16283-2 UNE-EN ISO 140-7 UNE-EN ISO 16283-1 + 1 more
View Profile
ENAC LE285 Alacant, ES
UNE-EN ISO 27888 SM 2540 UNE-EN ISO 8467 UNE-EN ISO 7027-1 UNE-EN ISO 10523 + 3 more
View Profile

No matching labs found.

Industries

Automotive and vehicle noise source characterization Machinery and equipment acoustic testing Building services and HVAC noise assessment Aerospace and transportation noise evaluation Environmental noise consulting and source identification

Related Standards

  • ISO 9614-2 Determination of sound power levels of noise sources by sound intensity — Part 2: Measurement by scanning
  • ISO 3744 Determination of sound power levels of noise sources using sound pressure — Precision method in anechoic and hemi-anechoic rooms
  • ISO 9613-1 Attenuation of sound during propagation outdoors — Part 1: Calculation of the absorption of sound by the atmosphere

Other Test Methods

0 labs selected
Compare