ISO 3747:2010
Sound Power Level — In-Situ Reference Source Method
This engineering/survey method determines sound power levels using a calibrated reference sound source to account for acoustic environmental conditions during in-situ measurements. It is particularly useful for large or immobile equipment where laboratory testing is impractical, and for on-site verification of noise compliance. The reference source approach compensates for acoustic environmental effects, improving accuracy compared to basic survey methods. Accreditation ensures proper reference source maintenance and measurement protocols are followed. This method is essential for field acceptance testing and environmental noise assessments.
What it measures
- Sound power level (Lw) referenced to 1 pW
- A-weighted and frequency-weighted sound power
- Environmental acoustic correction factors
- In-situ acoustic performance
🇩🇪
DIN EN ISO 3746
🇬🇧
BS EN ISO 3746
🇫🇷
NF EN ISO 3746
🇮🇹
UNI EN ISO 3746
🇪🇸
UNE EN ISO 3746
🇳🇱
NEN EN ISO 3746
🇩🇪
DIN EN ISO 9614-1
🇬🇧
BS EN ISO 9614-1
🇫🇷
NF EN ISO 9614-1
🇮🇹
UNI EN ISO 9614-1
🇪🇸
UNE EN ISO 9614-1
🇳🇱
NEN EN ISO 9614-1
1,868
Accredited labs
20
Countries
Showing 226–250 of 906 labs
HFB Engineering
Active
DIN EN ISO 10666
DIN 53438-3
rs738409
DIN EN 1382
DIN EN 1383
+ 3 more
Gleichspannung a)
/ Messgeräte
> 600 kV
Messsysteme, Teiler
> 5 kV
+ 3 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-4: 2012
VDE 0847-4-4
IEC 61000-4-5: 2005
+ 3 more
HLK Stuttgart
Active
DIN EN 442-2
DIN EN 16430-1
DIN EN 16430-2
DIN EN 16430-3
DIN 4703-3
+ 3 more
HYDAC Systems & Services
Active
Gleichspannung 0 µV
Messgeräte > 20 mV
Messgeräte > 200 mV
> 2 V
> 20 V
+ 3 more
HaBu Hauck Prüftechnik
Active
Härte *) 20 HRA
Härtevergleichsplatten 20 HRB
nach Rockwell Verfahren 20 HRC
40 HRD
60 HRF
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Kraft (WPM)
Werkstoffprüfmaschinen
Acoustics — tonality assessment (DIN 456
messeinrichtungen von
Härte (WPM) 30 HBW
+ 3 more
Absolutdruck p
abs
> 41 bar
Negativer und
positiver Überdruck
+ 3 more
Hohenstein Laboratories
Active
DIN 53160
DIN 54034
DIN 54056
DIN EN 20105-A02
DIN EN 20105-N01
+ 3 more
Taupunkttemperatur
thermometer, -80 °C bis
Railway braking — urban guided transport
> -35 °C bis
Temperatur- −35 °C bis
+ 3 more
Horiba Europe
Active
0,6 bar
ver Überdruck p e *
Absolutdruck p abs 100 mbar
> 70 mbar
Gaskonzentration
+ 3 more
–1 bar
Positiver und negativer
Positiver Überdruck p e
> 0,0 bar
Absolutdruck p abs 0,25 bar
+ 3 more
Hottinger Brüel & Kjaer
Active
Übertragungsmaß von
Messmikrofonen oder
Freifeld-Leerlauf- 20 Hz
Freifeld -Übertragungsmaß
Vorverstärker, nach IEC
+ 3 more
DIN ISO 5667-5 (A 14)
DIN EN ISO 19458 (K 19)
DIN 19643-1
DIN EN ISO 7887 (C 1)
DIN 38404-C 4
+ 3 more
Hydrodata
Active
DIN EN ISO 5667-1 (A 4)
DIN 38402-A 12
DIN 38402-A 13
DIN 38402-A 15
DIN EN ISO 5667-3 (A 21)
+ 3 more
Hydrotechnik
Active
Negativer und
Positiver Überdruck p e
> 0,015 bar
Überdruck p
(ein- oder mehrgängige
+ 3 more
HygCen Germany
Active
DIN EN ISO 10993-1
DIN EN ISO 10993-5
DIN EN ISO 17405
ISO 10993-23
DIN EN ISO 10993-18
+ 3 more
Hygiene Nord
Active
DIN EN ISO 10993-5
DIN EN ISO 10993-1
DIN EN ISO 11737-2
DIN EN 1040
DIN EN IEC 60601-2-75
+ 3 more
Hygiene-Institut AYSID
Active
DIN 1946-4
DIN EN 13098
DIN EN ISO 17141
ISO 14644-3
DIN 12980
+ 1 more
Innen- und Tiefenmaße
Konventioneller
Wägewert/
Massenormale
Festkörpervolumen
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN EN 61800-5-1: 2017
IFB Eigenschenk
Active
DIN EN ISO 17892-2
DIN EN ISO 17892-3
DIN EN ISO 17892-4
DIN 18121-2
DIN 18125-2
+ 3 more
No matching labs found.