DIN 45669-1:1995

Vibration Measuring Instruments Specification

This standard specifies the requirements and technical characteristics for vibration measuring instruments used to assess seismic, environmental, and occupational vibration. The test method defines performance criteria, calibration procedures, and measurement uncertainty limits for instruments designed to detect and quantify vibration in buildings, industrial facilities, and other structures. Accurate vibration measurement is essential for structural health monitoring, vibration exposure assessment, and compliance with occupational safety limits. Acoustics laboratories and environmental monitoring organizations require these instruments to be calibrated and verified according to this standard. ISO 17025 accreditation ensures measurement traceability and instrument performance validation.

What it measures

  • Vibration acceleration, velocity, and displacement
  • Frequency response and calibration accuracy
  • Vibration exposure levels and intensity
  • Instrument sensitivity and measurement uncertainty
  • Compliance with metrological performance specifications
🇩🇪 DIN EN ISO 16063-41 🇬🇧 BS EN ISO 16063-41 🇫🇷 NF EN ISO 16063-41 🇮🇹 UNI EN ISO 16063-41 🇪🇸 UNE EN ISO 16063-41 🇳🇱 NEN EN ISO 16063-41 🇩🇪 DIN EN ISO 20816-1 🇬🇧 BS EN ISO 20816-1 🇫🇷 NF EN ISO 20816-1 🇮🇹 UNI EN ISO 20816-1 🇪🇸 UNE EN ISO 20816-1 🇳🇱 NEN EN ISO 20816-1
1,868 Accredited labs
20 Countries

Showing 276–300 of 906 labs

DAkkS D-ML-17347-01-00 Ulm, DE
Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Lymphozyten Leukozyten + 3 more
View Profile
DAkkS D-ML-18337-01-00 München, DE
Bacillus anthracis Antikörper Direkter Coombstest polyvalent Brucella spp. IgG, IgM Antikörper Francisella tularensis-Antikörper polyvalent, IgG, IgM + 3 more
View Profile
DAkkS D-K-18657-01-01 Emmerthal, DE
Kurzschlussstrom 0,5 mA 0,1 V Füllfaktor Solarzellen* 25 % 0,01 mW THD U 0,1 % + 3 more
View Profile
DAkkS D-PL-19759-01-05 Duisburg, DE
Erythrozyten im 1,5.10121-1 DIN EN ISO 10121-2 DIN EN ISO 16890-1 DIN EN ISO 16890-2 DIN EN ISO 16890-3 + 3 more
View Profile
DAkkS D-PL-19125-01-00 Bonn, DE
DIN EN IEC 60255-1 VDE 0435-300 DIN EN 60255-151 VDE 0435-3151 IEC 60255-151 + 3 more
View Profile
DAkkS D-PL-11307-01-00 Hamburg, DE
DIN EN ISO 12185 ASTM D 4052 DIN EN ISO 3405 ASTM D 86 DIN EN 13016-1 + 3 more
View Profile
DAkkS D-PL-14184-01-02 Fürth, DE
IEC 62321-2 DIN EN 61340-4-4 DIN EN 12472 DIN EN 16711-1 DIN EN 1264-5 + 3 more
View Profile
DAkkS D-PL-12085-01-01 Kaufbeuren, DE
IEC 61000-3-2: 2014 IEC 61000-3-3 IEC 61000-3-11: 2017 IEC 61000-3-12: 2011 IEC 61000-4-2: 2008 + 3 more
View Profile
DAkkS D-K-15061-01-00 Nettetal, DE
Härte* 20 HRA Härtevergleichsplatten 20 HRB 20 HRC 40 HRD + 3 more
View Profile
DAkkS D-K-21494-01-00 Weiden i. d. OPf., DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen Innen- und Tiefenmaße Konventioneller + 2 more
View Profile
DAkkS D-K-18423-01-00 Aschaffenburg, DE
Ebenheitsabweichung verkörperungen z.B. platten nach DIN 876:1984 Geradheitsabweichung ebener Flächen, z.B. + 3 more
View Profile

Johs. Boss

Active
DAkkS D-K-21417-01-00 Albstadt, DE
(ein- und mehrgängige winde mit geradlinigen unsymmetrischem Profil 0,5 mm bis 6 mm) Außengewinde Nenndurchmesser + 3 more
View Profile
DAkkS D-ML-13135-01-00 Würzburg, DE
Obligat anaerobe Bakterien mikroaerophile Bakterien ESBL-Bildner (multiresistente gramnegative säurefeste Stäbchen + 3 more
View Profile
DAkkS D-ML-13135-03-01 Würzburg, DE
CD45 Percp+CD16+56+CD3 CD4 CD45 Percp+CD4+CD8 Adalimumab Anti-Adalimumab Antikörper + 3 more
View Profile

Jurjanz

Active
DAkkS D-K-15085-01-01 Schkeuditz, DE
Parallelendmaße aus 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße aus > 100 mm Messschieber für 1350 mm + 3 more
View Profile
DAkkS D-PL-12119-01-00 Wuppertal, DE
DIN EN IEC 60947-5 IEC 60947-5-1 IEC 60947-5-2 DIN EN 60947-5 IEC 60947-5-3 + 3 more
View Profile
DAkkS D-K-17233-01-00 Hochdorf-Assenheim, DE
Härteprüfmaschinen nach 100 HBW Brinell- und 226 HBW messeinrichtungen von Härteprüfmaschinen + 3 more
View Profile
DAkkS D-ML-13391-01-00 Frankfurt am Main, DE
basophile, eosinophile, Granulozyten Differenzialblutbild Erythrozyten Erythrozytenverteilungsbreite (RDW) + 3 more
View Profile
DAkkS D-PL-22093-01-00 Ratingen, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-4: 2012 VDE 0847-4-4 IEC 61000-4-5: 2005 + 3 more
View Profile
DAkkS D-PL-12091-01-01 Forchtenberg, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-21779-01-00 Berlin, DE
Gleichspannung 100 µV Messgeräte 220 mV > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-K-20795-01-01 Waldaschaff, DE
Railway brake — magnetic track brakes (U − Ebenheit − Geradheit − Winkelnormale auch als Vor-Ort-Kalibrierung + 3 more
View Profile
DAkkS D-PL-11068-09-00 Karlsruhe, DE
DIN EN 60034-15 VDE 0530-15 IEC 60034-15 DIN EN 60044-7 VDE 0414-44-7 + 3 more
View Profile
DAkkS D-K-11068-01-00 Eggenstein-Leopoldshafen, DE
Luftkerma/-leistung Dosis Dosisleistung
View Profile

Kern & Sohn

Active
DAkkS D-K-19408-01-01 Balingen, DE
nichtselbsttätige − Waagen Festkörpervolumen Wägewert/ Masse oder + 3 more
View Profile

No matching labs found.

Industries

Vibration monitoring and analysis services Building and structural engineering Occupational health and safety Industrial maintenance and diagnostics Environmental and seismic monitoring

Related Standards

  • ISO 16063-41 Methods for the calibration of vibration and shock transducers - Part 41: Calibration of hand-arm vibration meters
  • ISO 20816-1 Mechanical vibration - Measurement and evaluation of machine vibration - Part 1: General guidelines
  • EN 12639 Vibration measurement and evaluation of vibration on ships - Guidelines for measurement, evaluation and reporting of vibration with regard to habitability on merchant and naval ships

Other Test Methods

0 labs selected
Compare