EN 15153-2

Railway Automatic Train Protection and Warning Systems

This test evaluates the performance and reliability of automatic warning and train protection systems designed to prevent unsafe braking situations and collision hazards in railway operations. It verifies system response times, signal accuracy, and functional safety under normal and degraded operational conditions. Such systems are fundamental to modern railway safety infrastructure, protecting both mainline and urban transit operations. Accreditation ensures laboratories can comprehensively validate these critical safety systems against TSI performance requirements and EU Regulation 402/2013 on railway safety.

What it measures

  • Warning system activation timing and accuracy
  • Automatic brake application response characteristics
  • Signal transmission reliability and integrity
  • System performance during communication failures
  • Functional safety and hazard mitigation effectiveness
🇩🇪 DIN EN 15154-1 🇬🇧 BS EN 15154-1 🇫🇷 NF EN 15154-1 🇮🇹 UNI EN 15154-1 🇪🇸 UNE EN 15154-1 🇳🇱 NEN EN 15154-1 🇩🇪 DIN EN 50128 🇬🇧 BS EN 50128 🇫🇷 NF EN 50128 🇮🇹 UNI EN 50128 🇪🇸 UNE EN 50128 🇳🇱 NEN EN 50128
1,560 Accredited labs
17 Countries

Showing 251–275 of 849 labs

DAkkS D-PL-17201-01-00 Rheinmünster, DE
ISO 17987-6 ISO 17987-7 ISO 16845
View Profile
DAkkS D-K-20838-01-02 Bietigheim, DE
Taupunkttemperatur Railway braking — urban guided transport Railway vehicle body structural requirem Railway bogies — wheelsets and bogies st Elektrische + 3 more
View Profile
DAkkS D-PL-14095-03-02 Hamburg, DE
DIN 38402-A 12 DIN ISO 5667-5 (A 14) DIN EN ISO 5667-6 (A 15) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile
DAkkS D-ML-17347-01-00 Ulm, DE
Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Lymphozyten Leukozyten + 3 more
View Profile
DAkkS D-ML-18337-01-00 München, DE
Bacillus anthracis Antikörper Direkter Coombstest polyvalent Brucella spp. IgG, IgM Antikörper Francisella tularensis-Antikörper polyvalent, IgG, IgM + 3 more
View Profile
DAkkS D-K-18657-01-01 Emmerthal, DE
Kurzschlussstrom 0,5 mA 0,1 V Füllfaktor Solarzellen* 25 % 0,01 mW THD U 0,1 % + 3 more
View Profile
DAkkS D-PL-19759-01-05 Duisburg, DE
Erythrozyten im 1,5.10121-1 DIN EN ISO 10121-2 DIN EN ISO 16890-1 DIN EN ISO 16890-2 DIN EN ISO 16890-3 + 3 more
View Profile
DAkkS D-PL-19125-01-00 Bonn, DE
DIN EN IEC 60255-1 VDE 0435-300 DIN EN 60255-151 VDE 0435-3151 IEC 60255-151 + 3 more
View Profile
DAkkS D-PL-11307-01-00 Hamburg, DE
DIN EN ISO 12185 ASTM D 4052 DIN EN ISO 3405 ASTM D 86 DIN EN 13016-1 + 3 more
View Profile
DAkkS D-PL-14184-01-02 Fürth, DE
IEC 62321-2 DIN EN 61340-4-4 DIN EN 12472 DIN EN 16711-1 DIN EN 1264-5 + 3 more
View Profile
DAkkS D-PL-12085-01-01 Kaufbeuren, DE
IEC 61000-3-2: 2014 IEC 61000-3-3 IEC 61000-3-11: 2017 IEC 61000-3-12: 2011 IEC 61000-4-2: 2008 + 3 more
View Profile
DAkkS D-K-19500-01-01 Dillenburg, DE
Gleichspannung 1 Gleichstrom- und Nieder- 10 mV > 10 V Gleichstromstärke 1 > 1mA + 3 more
View Profile
DAkkS D-K-15061-01-00 Nettetal, DE
Härte* 20 HRA Härtevergleichsplatten 20 HRB 20 HRC 40 HRD + 3 more
View Profile
DAkkS D-K-15129-01-01 Fulda, DE
Temperaturmessgrößen (Härteskalen HV0,01 Widerstandssensor * direktanzeigende > 200 °C Messumformer mit + 3 more
View Profile
DAkkS D-K-21494-01-00 Weiden i. d. OPf., DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO elektronische Waagen Innen- und Tiefenmaße Konventioneller + 2 more
View Profile
DAkkS D-K-18423-01-00 Aschaffenburg, DE
Ebenheitsabweichung verkörperungen z.B. platten nach DIN 876:1984 Geradheitsabweichung ebener Flächen, z.B. + 3 more
View Profile

Johs. Boss

Active
DAkkS D-K-21417-01-00 Albstadt, DE
(ein- und mehrgängige winde mit geradlinigen unsymmetrischem Profil 0,5 mm bis 6 mm) Außengewinde Nenndurchmesser + 3 more
View Profile
DAkkS D-ML-13135-01-00 Würzburg, DE
Obligat anaerobe Bakterien mikroaerophile Bakterien ESBL-Bildner (multiresistente gramnegative säurefeste Stäbchen + 3 more
View Profile
DAkkS D-ML-13135-03-01 Würzburg, DE
CD45 Percp+CD16+56+CD3 CD4 CD45 Percp+CD4+CD8 Adalimumab Anti-Adalimumab Antikörper + 3 more
View Profile
DAkkS D-PL-12119-01-00 Wuppertal, DE
DIN EN IEC 60947-5 IEC 60947-5-1 IEC 60947-5-2 DIN EN 60947-5 IEC 60947-5-3 + 3 more
View Profile
DAkkS D-K-19781-01-02 Hagen, DE
Temperaturmessgrößen Widerstandsthermometer* Railway braking — urban guided transport Railway vehicle body structural requirem Widerstandssensor * + 3 more
View Profile
DAkkS D-K-17233-01-00 Hochdorf-Assenheim, DE
Härteprüfmaschinen nach 100 HBW Brinell- und 226 HBW messeinrichtungen von Härteprüfmaschinen + 3 more
View Profile
DAkkS D-K-18972-01-01 Hemmingen, DE
eingängige zylindrische Einstellnormale Lehrdorne Durchmesser 1 mm Prüfstifte + 3 more
View Profile
DAkkS D-ML-13391-01-00 Frankfurt am Main, DE
basophile, eosinophile, Granulozyten Differenzialblutbild Erythrozyten Erythrozytenverteilungsbreite (RDW) + 3 more
View Profile
DAkkS D-PL-12091-01-01 Forchtenberg, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile

No matching labs found.

Industries

Railway signalling system manufacturers Rolling stock integrators Railway infrastructure operators Rail safety certification bodies Transit authority operators

Related Standards

  • EN 15154-1 Railway applications - Automatic warning and train protection systems - System architecture
  • EN 50128 Railway applications - Communication, signalling and processing systems - Safety-related electronic systems for signalling
  • EU Regulation 402/2013 Regulation on a single European railway area - Railway safety

Other Test Methods

0 labs selected
Compare