EN 15153-2

Railway Automatic Train Protection and Warning Systems

This test evaluates the performance and reliability of automatic warning and train protection systems designed to prevent unsafe braking situations and collision hazards in railway operations. It verifies system response times, signal accuracy, and functional safety under normal and degraded operational conditions. Such systems are fundamental to modern railway safety infrastructure, protecting both mainline and urban transit operations. Accreditation ensures laboratories can comprehensively validate these critical safety systems against TSI performance requirements and EU Regulation 402/2013 on railway safety.

What it measures

  • Warning system activation timing and accuracy
  • Automatic brake application response characteristics
  • Signal transmission reliability and integrity
  • System performance during communication failures
  • Functional safety and hazard mitigation effectiveness
🇩🇪 DIN EN 15154-1 🇬🇧 BS EN 15154-1 🇫🇷 NF EN 15154-1 🇮🇹 UNI EN 15154-1 🇪🇸 UNE EN 15154-1 🇳🇱 NEN EN 15154-1 🇩🇪 DIN EN 50128 🇬🇧 BS EN 50128 🇫🇷 NF EN 50128 🇮🇹 UNI EN 50128 🇪🇸 UNE EN 50128 🇳🇱 NEN EN 50128
1,323 Accredited labs
15 Countries

Showing 501–525 of 1,323 labs

ITALCERTIFER

Active
ACCREDIA 00447 Firenze, IT
EN 14531-1 DIN EN 50215 UNI EN 14531-2 DIN EN 16334 DIN EN 15355 + 3 more
View Profile
UKAS 0123 Aberdeen, GB
DC Resistance DC VOLTAGE Temperatur-Simulation AC CURRENT Base metal thermocouples + 3 more
View Profile
UKAS 0102 Grays, GB
ASTM D3338 ASTM D 2624 ASTM D 5006 ASTM D 2386 ASTM D7153 + 3 more
View Profile
UKAS 1158 Chester, GB
UK 3725 based on ASTM D2163 and BS EN 15984:2011-07 IP 411, ISO 6251 ASTM D6667 mod ISO 8973 modified + 3 more
View Profile
DAkkS D-PL-11283-01-01 Seevetal, DE
ISO 6508-1 Charpy impact test (ISO 148-1) Tensile testing of metallic materials (I BS EN ISO 9015-2 BS EN ISO 9016:2022 + 3 more
View Profile
DAkkS D-K-12001-01-01 Ottobrunn, DE
- Gleichstromwiderstand / Messgeräte Quellen >100 Ω > 10 kΩ + 3 more
View Profile
DAkkS D-PL-12023-01-01 Darmstadt, DE
DIN 56912 DIN EN 12198-1 DIN EN 12198-2 DIN EN 12198-3 DIN EN 60825-1 + 3 more
View Profile
DAkkS D-PL-17201-01-00 Rheinmünster, DE
ISO 17987-6 ISO 17987-7 ISO 16845
View Profile
DAkkS D-K-20838-01-02 Bietigheim, DE
Taupunkttemperatur Railway braking — urban guided transport Railway vehicle body structural requirem Railway bogies — wheelsets and bogies st Elektrische + 3 more
View Profile
UKAS 8401 Drighlington, GB
Appendix 5 of HSG 227 (2004))
View Profile
DAkkS D-PL-14095-03-02 Hamburg, DE
DIN 38402-A 12 DIN ISO 5667-5 (A 14) DIN EN ISO 5667-6 (A 15) DIN EN ISO 19458 (K 19) DIN 19643-1 + 3 more
View Profile
DAkkS D-ML-17347-01-00 Ulm, DE
Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Lymphozyten Leukozyten + 3 more
View Profile
DAkkS D-PL-19060-01-01 Wettenberg, DE
ISO 2178 ISO 4892-2: 2013-03 UNE-EN ISO 11998 BS EN ISO 16474-3:2021 ISO 6270-1 + 3 more
View Profile
DAkkS D-ML-18337-01-00 München, DE
Bacillus anthracis Antikörper Direkter Coombstest polyvalent Brucella spp. IgG, IgM Antikörper Francisella tularensis-Antikörper polyvalent, IgG, IgM + 3 more
View Profile

CalTeC

Active
DAkkS D-K-18657-01-01 Emmerthal, DE
Kurzschlussstrom 0,5 mA 0,1 V Füllfaktor Solarzellen* 25 % 0,01 mW THD U 0,1 % + 3 more
View Profile
DAkkS D-PL-19125-01-00 Bonn, DE
DIN EN IEC 60255-1 VDE 0435-300 DIN EN 60255-151 VDE 0435-3151 IEC 60255-151 + 3 more
View Profile
DAkkS D-PL-11307-01-00 Hamburg, DE
DIN EN ISO 12185 ASTM D 4052 DIN EN ISO 3405 ASTM D 86 DIN EN 13016-1 + 3 more
View Profile
DAkkS D-PL-14184-01-02 Fürth, DE
IEC 62321-2 DIN EN 61340-4-4 DIN EN 12472 DIN EN 16711-1 DIN EN 1264-5 + 3 more
View Profile
DAkkS D-PL-12085-01-01 Kaufbeuren, DE
IEC 61000-3-2: 2014 IEC 61000-3-3 IEC 61000-3-11: 2017 IEC 61000-3-12: 2011 IEC 61000-4-2: 2008 + 3 more
View Profile
RvA L377 Geleen, NL
DIN EN ISO 10675-1 DIN EN ISO 19458 DIN EN ISO 179-1 NEN 6953 DIN EN ISO 10675-2 + 3 more
View Profile

Intona

Active
UKAS 10273 Dundee, GB
and Appx. 3 of HSG 227 (2004)) Executive guides HSG 264 (2012) (HSG 264, 2012)
View Profile
DAkkS D-K-19500-01-01 Dillenburg, DE
Gleichspannung 1 Gleichstrom- und Nieder- 10 mV > 10 V Gleichstromstärke 1 > 1mA + 3 more
View Profile
DAkkS D-K-15061-01-00 Nettetal, DE
Härte* 20 HRA Härtevergleichsplatten 20 HRB 20 HRC 40 HRD + 3 more
View Profile

J B-Monitor

Active
UKAS 2075 Colwyn Bay, GB
(HSG 248) – 2021 No 1 based on HSG 248 – 2021 (PCM) based on HSG 248 – 2021 No 3 based on HSG 248 – 2021 (PCM) based on HSG 248 + 1 more
View Profile
ENAC LC10.259 Cartagena, ES
CEM EL-014 CEM EL CEM EL-001 CEM ME
View Profile

No matching labs found.

Industries

Railway signalling system manufacturers Rolling stock integrators Railway infrastructure operators Rail safety certification bodies Transit authority operators

Related Standards

  • EN 15154-1 Railway applications - Automatic warning and train protection systems - System architecture
  • EN 50128 Railway applications - Communication, signalling and processing systems - Safety-related electronic systems for signalling
  • EU Regulation 402/2013 Regulation on a single European railway area - Railway safety

Other Test Methods

0 labs selected
Compare