EN 16584-2

Railway Wheel Squeal and Curve Noise Assessment

This test method characterizes squeal and curve noise generated by railway wheels during operation, particularly in tight curves and low-adhesion conditions. The evaluation focuses on wheel-rail interaction noise to identify problematic frequency bands and noise generation mechanisms. Railway operators and wheel manufacturers use this test to develop noise mitigation strategies and ensure compliance with environmental noise directives. Accreditation validates that testing facilities can accurately measure and report wheel-generated noise for European railway standardization and regulatory compliance.

What it measures

  • Squeal frequency content and magnitude
  • Curve-induced noise characteristics
  • Sound pressure levels in critical frequency bands
  • Noise generation under specific track geometry conditions
  • Wheel surface roughness correlation with noise
🇩🇪 DIN EN 16185-1 🇬🇧 BS EN 16185-1 🇫🇷 NF EN 16185-1 🇮🇹 UNI EN 16185-1 🇪🇸 UNE EN 16185-1 🇳🇱 NEN EN 16185-1 🇩🇪 DIN EN 13979-1 🇬🇧 BS EN 13979-1 🇫🇷 NF EN 13979-1 🇮🇹 UNI EN 13979-1 🇪🇸 UNE EN 13979-1 🇳🇱 NEN EN 13979-1
1,273 Accredited labs
15 Countries

Showing 251–275 of 1,273 labs

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
ENAC LC10.204 Fuenlabrada, ES
0 mV  U < 330 mV 330 mV  U < 3,3 V 3,3 0 mV  U < 120 mV 120 mV  U < 1,2 V 1,2 0 A  I  330 A 330 A < I  3,3 mA 3, 20 A  I  1025 A 20 A  I  1025 A F = 50 Hz + 3 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
ENAC LC10.254 Sevilla, ES
50 ∙ 10-9 mol/mol ≤ C ≤ 237 · 10-9 mol/m 30∙ 10-9 mol/mol ≤ C ≤ 500 ∙ 10-9 mol/mo 50 ∙ 10-9 mol/mol ≤ C ≤ 1000 · 10-9 mol/ 50 ∙ 10-9 mol/mol ≤ C ≤ 237∙ 10-9 mol/mo 0,5 ∙ 10-9 mol/mol ≤ C ≤ 15 ∙ 10-9 mol/m + 1 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
UKAS 4303 Ammanford, GB
1) MS08P based on BS EN ISO MS02P based on BS EN ISO MS03P based on BS EN ISO MS06P based on BS EN ISO MF07P based on BS EN ISO + 3 more
View Profile
DAkkS D-K-23327-01-01 Bad Camberg, DE
Metrologic Group GmbH, nalen von: Wernau, D Neuss, D ≤ 1515 mm Wetzlar, D S.p.A., Turin, I + 3 more
View Profile
ACCREDIA 02012 Roma, IT
ETSI EN 319 412 ETSI EN 319 401 ETSI EN 319 411-2 ETSI EN 319 411-1
View Profile
DAkkS D-PL-17009-06-00 Wiesbaden, DE
DIN EN 60950-1 EN IEC 62368-1 DIN EN 60204-1 DIN EN 60825-1 DIN EN 61010-1 + 3 more
View Profile
DAkkS D-PL-17009-07-02 Köln, DE
IEC 60335-1: 2010 IEC 60335-2-29 DIN EN 60335-2-29 IEC 60335-2-65 DIN EN 60335-2-65 + 3 more
View Profile

No matching labs found.

Industries

Railway wheel manufacturers Railway operators and infrastructure Rolling stock manufacturers Track maintenance and rail operators Environmental noise management

Related Standards

  • EN 16185-1 Railway applications - Brake friction pairs - Part 1: Friction behaviour assessment and acceptance criteria
  • EN 13979-1 Railway applications - Braking systems - Part 1: General requirements and definitions
  • EN ISO 3095 Railway applications - Acoustics - Measurement of noise emitted by accelerating and decelerating trains

Other Test Methods

0 labs selected
Compare