EN 16584-2
Railway Wheel Squeal and Curve Noise Assessment
This test method characterizes squeal and curve noise generated by railway wheels during operation, particularly in tight curves and low-adhesion conditions. The evaluation focuses on wheel-rail interaction noise to identify problematic frequency bands and noise generation mechanisms. Railway operators and wheel manufacturers use this test to develop noise mitigation strategies and ensure compliance with environmental noise directives. Accreditation validates that testing facilities can accurately measure and report wheel-generated noise for European railway standardization and regulatory compliance.
What it measures
- Squeal frequency content and magnitude
- Curve-induced noise characteristics
- Sound pressure levels in critical frequency bands
- Noise generation under specific track geometry conditions
- Wheel surface roughness correlation with noise
🇩🇪
DIN EN 16185-1
🇬🇧
BS EN 16185-1
🇫🇷
NF EN 16185-1
🇮🇹
UNI EN 16185-1
🇪🇸
UNE EN 16185-1
🇳🇱
NEN EN 16185-1
🇩🇪
DIN EN 13979-1
🇬🇧
BS EN 13979-1
🇫🇷
NF EN 13979-1
🇮🇹
UNI EN 13979-1
🇪🇸
UNE EN 13979-1
🇳🇱
NEN EN 13979-1
1,516
Accredited labs
17
Countries
Showing 951–975 of 1,516 labs
Microtech Services (Wessex)
Active
ISO 7251
# = 100 A
ISO 6888-3
1) A:2b based on ISO 4833-2:2013 Amd 1:2
2) A:6c based on ISO 21528-1:2017 by mos
+ 1 more
Mimete Srl Unipersonale
Active
ASTM B212-21
ASTM E1019-24
ASTM B527-24
BS EN ISO 3923-1
ASTM B417-22
+ 3 more
Minebea Intec Bovenden
Active
Konventioneller
Wägewert/
Massenormale
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
+ 3 more
Bacillus cereus Toxin
Clostridium perfringens
Salmonella spp.
Shigella spp.
Staphylococcus aureus Toxin
+ 3 more
ETSI EN 319 412
ETSI EN 319 401
ETSI EN 319 411-2
ETSI EN 319 411-1
Ministry of Defence
Active
Specific Values
Specific values (continued)
ELECTRICAL
Other Values
AC CURRENT
+ 3 more
Mitutoyo Deutschland
Active
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 10 mm
Parallelendmaße > 100 mm
+ 3 more
Mobiler Kalibrierdienst Fini
Active
Gleichspannung 3 mV
Messgeräte 10 mV
> 100 mV
> 220 mV
> 11 V
+ 3 more
Temperatur 50 °C
Railway brake handbooks (UIC 547)
1) In den CMC sind die erweiterten Messu
Moorcroft Controls
Active
DC CURRENT
Gas pressure (gauge)
ELECTRICAL
DC VOLTAGE
Measurement
+ 3 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
Mühlenkreiskliniken AöR Institut für Laboratoriumsmedizin, Transfusionsmedizin und Mikrobiologie
Active
Differentialblutbild
Kleines Blutbild (maschinell)
Thrombozyten
Unreife Thrombozyten (IPF)
Urinsediment (maschinell)
+ 3 more
DIN EN ISO 717-1
DIN EN ISO 717-2
DIN EN ISO 10140-2
DIN EN ISO 10140-4
DIN EN ISO 10140-5
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN ISO 8297
DIN EN ISO 12354-4
+ 3 more
München Klinik gGmbH Medizet - Institut für Laboratoriumsmedizin und medizinische Mikrobiologie
Active
Hämoglobin A1c
Hämoglobin-Differenzierung
Erythrozyten
Basophile Granolozyten
Eosinophile Granulozyten
+ 3 more
NANO LABO
Active
NF X43-050 (parties utiles de
NF X 46-032
DIN EN ISO 11885
NF X43-050 (parties utiles de la
NF ISO 22262-1 (parties utiles
+ 1 more
NATEC Sensors
Active
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
Gleichspannung U
(Simulation des Signals
generators)
+ 3 more
NEMKO
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
NORMEC QS
Active
NEN-EN 13361
ISO 13362
NEN-EN 13491
DIN EN 13493
NEN-EN 13492
+ 3 more
NSF Wales Limited
Active
BS EN ISO 7686:2005
DIN EN 997
DIN EN 13079
DIN ISO 10381-7
DIN EN 14622
+ 3 more
Narda Safety Test Solutions
Active
Elektrische Feldstärke /
2 V/m
2,5 V/m
1 V/m
Magnetische Feldstärke /
+ 3 more
No matching labs found.