EN 17285

Railway Composite Brake Blocks - Requirements

This test method establishes performance requirements and acceptance criteria for composite (non-asbestos) brake blocks used in freight wagon braking systems. It evaluates friction characteristics, thermal stability, wear resistance, and compatibility with brake disc or wheel surfaces under representative operational conditions. Freight operators and brake block manufacturers use this test to ensure component reliability and safe braking performance in heavy-duty rail transport. Accreditation is critical for laboratories conducting brake block qualification testing to provide independent verification of compliance with European technical specifications for freight wagon safety.

What it measures

  • Coefficient of friction under varied temperatures
  • Wear rate and durability characteristics
  • Thermal stability and fade resistance
  • Compatibility with disc or wheel materials
  • Dimensional stability and surface integrity
🇧🇪 NBN EN 16185-1 🇩🇪 DIN EN 16185-1 🇬🇧 BS EN 16185-1 🇫🇷 NF EN 16185-1 🇮🇹 UNI EN 16185-1 🇪🇸 UNE EN 16185-1 🇳🇱 NEN EN 16185-1 🇧🇪 NBN EN 13979-1 🇩🇪 DIN EN 13979-1 🇬🇧 BS EN 13979-1 🇫🇷 NF EN 13979-1 🇮🇹 UNI EN 13979-1
3,525 Accredited labs
21 Countries

Showing 3,426–3,450 of 3,525 labs

UKAS 8836 Wirral, GB
Calcium Helicobacter pylori Hepatitis-B-surface-Antigen Herpes simplex virus 1 Herpes simplex virus 2 + 3 more
View Profile
UKAS 9595 Wirral, GB
MRSA VRE Coronavirus 229E Coronavirus HKU1 Coronavirus NL63 + 3 more
View Profile
DAkkS D-K-20386-01-01 Meppen, DE
1) In den CMC sind die erweiterten Messu DIN EN ISO 3650:1999 > 300 mm Bügelmessschrauben 0 mm Feinzeiger + 3 more
View Profile
DAkkS D-PL-11105-01-01 Sinzheim, DE
(p.Ala222Val); dbSNP rs1801133 dbSNP rs1801133 und rs1801131 EN ISO 11925-2 DIN V ENV 807 DIN CEN/TS 15082 + 3 more
View Profile
UKAS 8870 Worcester, GB
Formalin fixed paraffin | Mucopolysaccha Frozen tissue | HIS-Cryotomy using CM186 Frozen tissue | Cryostat Fixed tissue, excisional and | Using Sak Fixed tissue, excisional and | RM2245 Se + 3 more
View Profile
UKAS 8873 Worcester, GB
Anti-HCV Hepatitis-B-surface-Antigen anti-HAV total Mumps IgG Parvovirus IgG + 3 more
View Profile
UKAS 8907 Worcester, GB
D-Dimer Platelets Measurement Antibodies: | Adrenal Compatibility Testing: | Manual Biovue c + 3 more
View Profile
UKAS 23934 Worthing, GB
Adult Hearing Services | Otoscopy Adult Hearing Services | Profile Adult Hearing Services | Adjustments
View Profile
UKAS 7976 Wigan, GB
Audiology | Otoscopy Audiology | History Taking Audiology | Pure Tone Audiometry Audiology | Impression Taking Audiology | Hearing Aid Fitting + 3 more
View Profile
DAkkS D-K-15040-01-00 Wuppertal, DE
Charpy impact test (ISO 148-1) verwendete Abkürzungen: − Waagen nichtselbsttätigen elektronischen + 2 more
View Profile
DAkkS D-PL-17611-01-01 Wuppertal, DE
DIN EN ISO 10523 (C 5) DIN EN 27888 (C 8) DIN EN ISO 10304-1 (D 20) DIN EN ISO 11885 (E 22) DIN 38402-A 30 + 3 more
View Profile
UKAS 8628 Union Walk, GB
HbA1c Fibrinogen Helicobacter pylori Astrovirus Rotavirus A + 3 more
View Profile
DAkkS D-K-21902-01-00 Wilsdruff ST Kesselsdorf, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) 1) In den CMC sind die erweiterten Messu − Waagen + 2 more
View Profile
DAkkS D-K-21769-01-00 Obertraubling, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) − Waagen Optoelektronische + 1 more
View Profile
DAkkS D-K-15073-01-01 Niederkrüchten, DE
Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO Radiated emissions (CISPR 32) − Waagen Optoelektronische + 1 more
View Profile

XEFRA SRL

Active
ACCREDIA 01259 Tortona, IT
IEC 62279 DIN EN 60079-1 IEC 60079-1 DIN EN 60079-2 DIN EN 60079-11 + 3 more
View Profile
DAkkS D-PL-11122-01-00 Kloster Lehnin, DE
wie GR 1404 DIN EN ISO 22826 DIN EN ISO 3679 BS 1363-1 BS 1363-2: 1999 + 3 more
View Profile
DAkkS D-K-20615-01-00 Weilheim, DE
Tensile testing of metallic materials (I Vickers hardness test (ISO 6507) Railway braking — urban guided transport direktanzeigende > 200 °C Taupunkttemperatur + 3 more
View Profile
UKAS 2437 Udaipur 313 003, IN
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
UKAS 26226 York, GB
Ethanol Digoxin Cortisol Glucose AFP + 3 more
View Profile
UKAS 9844 Hull, GB
Ethanol Digoxin Cortisol AFP CEA + 3 more
View Profile
UKAS 9724 York, GB
Digoxin Cortisol Glucose CEA Phenytoin + 3 more
View Profile
UKAS 22188 Manchester, GB
22188 Manchester | Email: [email removed Maternal Blood in Streck tubes • Screeni Maternal Blood in Streck tubes • Screeni Maternal Blood in Streck tubes • Screeni Maternal Blood in Streck tubes • Screeni + 2 more
View Profile

Z LAB Srl

Active
ACCREDIA 01046 Cerea, IT
Sound power — engineering methods for sm Sound power — engineering method using a Sound power — survey method (ISO 3746) Room acoustics — reverberation time (ISO Railway pass-by noise measurement (ISO 3 + 3 more
View Profile
DAkkS D-ML-18420-01-00 Lübeck, DE
HbA1c Glucose Hämoglobin Alkalische Phosphatase Erythrozyten + 3 more
View Profile

No matching labs found.

Industries

Freight wagon operators Brake block manufacturers Brake system component suppliers Rolling stock maintenance providers Railway type-approval bodies

Related Standards

  • EN 16185-1 Railway applications - Brake friction pairs - Part 1: Friction behaviour assessment and acceptance criteria
  • EN 13979-1 Railway applications - Braking systems - Part 1: General requirements and definitions
  • EN 16834 Railway applications - Adhesion under braking and traction conditions

Other Test Methods

0 labs selected
Compare