UIC 644

Railway Coach Bogie Behavior Assessment

This standard specifies the behavior and performance requirements for Y25 bogie type coaching stock bogies, focusing on derailment resistance, curving performance, and stability characteristics. It provides test methods and acceptance criteria for evaluating bogie performance through simulation, calculation, and track testing to ensure safe operation across varying track geometries and speeds. Compliance verification is mandatory for coach manufacturers, bogie suppliers, and infrastructure operators to maintain interoperability and prevent accidents. Accredited testing ensures comprehensive evaluation against standardized criteria, reducing operational risks and supporting evidence-based vehicle certification.

What it measures

  • Derailment coefficient and safety margin against derailment
  • Lateral and vertical wheel loads on curves
  • Curve-climbing behavior and stability
  • Dynamic response to track irregularities and switches
  • Forces on bogie frame and guidance components
🇩🇪 DIN EN 14363 🇬🇧 BS EN 14363 🇫🇷 NF EN 14363 🇮🇹 UNI EN 14363 🇪🇸 UNE EN 14363 🇳🇱 NEN EN 14363
1,632 Accredited labs
19 Countries

Showing 476–500 of 875 labs

DAkkS D-ML-17445-01-00 Dessau-Roßlau, DE
WBC (Leukozyten) RBC (Erythrocyten) HGB (Hb) HCT (Hk) PLT (Thrombozyten) + 3 more
View Profile
DAkkS D-ML-18902-01-00 Rostock, DE
Chromosomensatz (angeboren) Chromosomensatz (erworben) Adrenogenitales Syndrom Angelman-Syndrom (15q11-Region, UBE3A) Mikrodeletionen; AZFa-c) + 3 more
View Profile
DAkkS D-ML-13237-01-00 Raubling, DE
HbA1c Basophile, automatisch Eosinophile, automatisch Erythrozyten, automatisch Leukozyten, automatisch + 3 more
View Profile
DAkkS D-ML-19175-01-00 Erfurt, DE
HbA1c Hämatokrit Hämoglobin Leukozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-18008-01-00 Raunheim, DE
HbA1c Blutbild, groß (Blutbild klein Hämoglobin, Hämatokrit, MCH, MCHC) Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-13182-01-00 Essen, DE
Leukozyten Erythrozyten Thrombozyten Hämatokrit MCV + 3 more
View Profile
DAkkS D-ML-13238-01-01 Göttingen, DE
Obligat anaerobe Bakterien Grampositive aerobe und anaerobe Kokken Enterokokken Mikrokokken + 3 more
View Profile
DAkkS D-ML-13445-01-01 Wernigerode, DE
automatische Zelldifferenzierung Erythrozyten Leukozyten Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-K-15048-01-01 Allmersbach im Tal, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße > 100 mm Messschieber für Außen-, 0 mm + 3 more
View Profile

Metrolution

Active
DAkkS D-K-21403-01-01 Aichhalden, DE
Metrosoft CM, Software einer Raumdiagona AG, Chur, CH ≤ 3333 mm Oberkochen, D GmbH, Wetzlar, D AG, Chur, CH ≤ 7500 mm
View Profile
DAkkS D-K-19120-01-01 Gießen, DE
Flüssigkeitsvolumen * Kolbenhubpipetten Manuell betätigte spritzen Mehrfachdispenser + 3 more
View Profile

MeßTechnikNord

Suspended
DAkkS D-PL-15086-02-01 Jena, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-15086-01-01 Wedel, DE
- Gleichspannung Messverstärker > 120 mV > 1 V > 12 V > 1000 V + 3 more
View Profile
DAkkS D-K-20451-01-00 Bovenden, DE
Konventioneller Wägewert/ Massenormale Charpy impact test (ISO 148-1) Salt spray / neutral salt fog test (ISO + 3 more
View Profile
DAkkS D-ML-19288-01-00 Stuttgart, DE
Bacillus cereus Toxin Clostridium perfringens Salmonella spp. Shigella spp. Staphylococcus aureus Toxin + 3 more
View Profile
DAkkS D-K-15096-01-00 Neuss, DE
Parallelendmaße 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße > 10 mm Parallelendmaße > 100 mm + 3 more
View Profile
DAkkS D-K-21161-01-01 Esslingen, DE
Gleichspannung 3 mV Messgeräte 10 mV > 100 mV > 220 mV > 11 V + 3 more
View Profile
DAkkS D-K-11292-01-00 Buchen Odenwald, DE
Temperatur 50 °C Railway brake handbooks (UIC 547) 1) In den CMC sind die erweiterten Messu
View Profile
DAkkS D-PL-19306-01-00 Oppenweiler, DE
IEC 61000-4-2: 2008 VDE 0847-4-2 IEC 61000-4-3: 2006 VDE 0847-4-3 IEC 61000-4-4: 2012 + 3 more
View Profile
DAkkS D-ML-20225-01-00 Minden, DE
Differentialblutbild Kleines Blutbild (maschinell) Thrombozyten Unreife Thrombozyten (IPF) Urinsediment (maschinell) + 3 more
View Profile
DAkkS D-PL-14119-01-01 Planegg, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN ISO 8297 DIN EN ISO 12354-4 + 3 more
View Profile
DAkkS D-ML-13106-01-01 München, DE
Hämoglobin A1c Hämoglobin-Differenzierung Erythrozyten Basophile Granolozyten Eosinophile Granulozyten + 3 more
View Profile

NATEC Sensors

Active
DAkkS D-K-15139-01-01 Garching, DE
Railway brakes — conditions for homologa − Durchfluss von Flüssigkeiten Gleichspannung U (Simulation des Signals generators) + 3 more
View Profile

NEMKO

Active
DAkkS D-PL-22131-01-01 Pfinztal, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile
DAkkS D-K-17726-01-00 Pfullingen, DE
Elektrische Feldstärke / 2 V/m 2,5 V/m 1 V/m Magnetische Feldstärke / + 3 more
View Profile

No matching labs found.

Industries

Coach and passenger vehicle manufacturers Bogie and suspension system suppliers Railway operators and depot maintenance Track infrastructure and maintenance organizations Vehicle type approval and certification bodies

Related Standards

  • UIC 518 Railway applications — Tests for the acceptance of running characteristics of railway vehicles
  • EN 14363 Railway applications — Running gear — Testing and validation of running behaviour and safety
  • UIC 505-1 Railway vehicles — gauge limits — Part 1: Rolling stock

Other Test Methods