ISO 3095:2013 / EN ISO 3095
Railway Pass-By Noise Measurement
ISO 3095 defines the standardized method for measuring and reporting noise emitted by railbound vehicles during pass-by at a fixed observer position. This is the primary standard used to assess compliance with European TSI Noise limits and national environmental regulations for passenger and freight trains. Manufacturers, railway operators, and regulatory authorities depend on this test to demonstrate noise performance, support fleet certification, and document compliance with noise reduction requirements. Accredited laboratories provide the independent, traceable measurements required for regulatory approval and public confidence in noise impact assessments.
What it measures
- Sound pressure level during pass-by (LAmax, dB(A))
- Noise emission per axle or per vehicle
- Frequency spectrum of pass-by noise
- Time-weighted sound exposure level
- Noise contribution by vehicle type and condition
🇩🇪
DIN EN ISO 3381
🇬🇧
BS EN ISO 3381
🇫🇷
NF EN ISO 3381
🇮🇹
UNI EN ISO 3381
🇪🇸
UNE EN ISO 3381
🇳🇱
NEN EN ISO 3381
🇩🇪
DIN EN ISO 14837-1
🇬🇧
BS EN ISO 14837-1
🇫🇷
NF EN ISO 14837-1
🇮🇹
UNI EN ISO 14837-1
🇪🇸
UNE EN ISO 14837-1
🇳🇱
NEN EN ISO 14837-1
1,273
Accredited labs
15
Countries
Showing 151–175 of 1,273 labs
Based on ISO 10312:2019 and ISO
SOP 16 by XRD (ISO BS EN
IEC 60945
IEC 61162-1
IEC 61162-2
IEC 61162-450
IEC 61162-460
+ 3 more
Radioaktivität 50 Bq/m³
Radon-222-
100 Bq/m³
tration in Luft
200 Bq/m³
+ 3 more
DIN EN ISO 2808
DIN EN ISO 3219-2
DIN EN ISO 3838
DIN EN 933-1
DIN EN 933-4
+ 3 more
Conformity assessment — requirements for
Railway composite brake blocks — require
0,2 kN
0,4 kN
100 kN
+ 3 more
Bundesministerium der Verteidigung Bundeswehrkrankenhaus Berlin Abteilung XVI Laboratoriumsmedizin
Active
NRBC-Normoblasten
Anteil unreifer Retikulozyten
Erythrozyten
DELTA-He
Leukozyten
+ 3 more
Blutungszeit PFA ADP
Blutungszeit PFA EPI
PFA-P2Y
Erythrozyten
Hämatokrit
+ 3 more
EN IEC 61000-4
DIN EN IEC 61000
VDE 0847-4
DIN EN 55016-2
DIN EN IEC 61000-6
+ 3 more
C G C Laboratory
Active
(HSG 248) – 2021
(PCM) based on HSG 248
SOP 5, based on HSG 248
SOP 4, based on HSG 248
/ Messgeräte
Radiometrie 100 µW/cm²
stärkemessgeräte
UV-A 365nm
Linearität der
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkürzungen:
ETSI EN 301 489-1: V2.2.3
EN 61000-3-2 and EN 61000-3-3
IEC 61000-6-1
IEC 61000-4-4: 2012
1.4 Electrostatic Discharge EN 61000-4
+ 3 more
C.W.E. Services
Active
(HSG 264, 2012)
HSG 227 (2004))
Safety Executive guides HSG 264
(2012) and App 3 of HSG 227
(HSG 248) – 2021
+ 3 more
CALTECNICA INGENIEROS
Active
(3 ± 0,5) 10-2 mol/mol (5 ± 0,5) 10-
(5 ± 0,5) 10-2 mol/mol
- 80 ˚C a 200 ˚C
- 20 ˚C a < 23 ˚C 23 ˚C a 40 ˚C > 40 ˚C
- 20 ˚C a 60 ˚C
+ 2 more
CANAGROSA LAB&SERVICES
Active
ISO 2808
ISO 48-4
UNE-EN ISO 2808
ISO 2409
UNE-EN ISO 2360
+ 3 more
CARTESY
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Kraft
Railway vehicles — specific test require
Railway — traction effort and braking fo
+ 3 more
(0,15 ± 0,02) · 10-2 mol/mol (0,50 ± 0,0
(6,0 ± 1,0) · 10-2 mol/mol (11,5 ± 2,0)
(10 ± 2) · 10-6 mol/mol (50 ± 8) · 10-6
(0,15 ± 0,02) · 10-2 mol/mol (0,30 ± 0,0
1,000 ± 0,100
+ 3 more
CATAS SpA
Active
ISO 9308-1
ISO 7899-2
DIN EN ISO 11205
DIN EN ISO 10304-1
ISO 14189
+ 3 more
DIN EN 13260
DIN EN 13261
DIN EN 13262
Railway end stop systems (EN 14752)
Railway vehicle body structural requirem
+ 3 more
UNE-EN 60567
IEC 60814
UNE-EN 61198
IEC 60247
UNE-EN 61619
+ 3 more
No matching labs found.