EN 50206-1

Main Line Railway Pantograph Testing

This test evaluates the mechanical and electrical performance of pantographs used on main line railway networks. It assesses contact force stability, dynamic behavior under catenary interaction, wear resistance, and electrical contact quality to ensure reliable current collection at high speeds. European railways and rolling stock manufacturers require this accreditation to certify pantograph compliance before deployment on main line services. Accredited testing ensures safety, reliability, and interoperability of railway electrification infrastructure across European networks.

What it measures

  • Contact force and force variations during operation
  • Mechanical stiffness and dynamic response
  • Wear of carbon or composite contact strips
  • Electrical contact resistance and arcing behavior
  • Interaction with various catenary geometries
🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2 🇩🇪 DIN EN 50317 🇬🇧 BS EN 50317 🇫🇷 NF EN 50317 🇮🇹 UNI EN 50317 🇪🇸 UNE EN 50317 🇳🇱 NEN EN 50317
1,399 Accredited labs
17 Countries

Showing 76–100 of 800 labs

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile
DAkkS D-K-11081-02-01 Chemnitz, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 auch Vor-Ort Kalibrierung bahntypischer –0,26 mm + 3 more
View Profile
DAkkS D-PL-11072-01-01 Freiberg, DE
DIN EN ISO 9012 ISO 22967 ISO 22968 (SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 + 3 more
View Profile
DAkkS D-K-17567-01-01 Lauf a. d. Pegnitz, DE
(ein- und mehrgängige zylindrische Außen- und metrischem Profil) Außengewinde Nenndurchmesser Flankendurchmesser 1 mm + 3 more
View Profile
DAkkS D-PL-11060-03-05 Stuttgart, DE
DIN EN ISO 5667-3 DIN EN ISO 15587-2 DIN EN 12457-4 DIN EN 13346 DIN EN 13657 + 3 more
View Profile
DAkkS D-PL-17438-01-04 Stuttgart, DE
IEC 60335-1: 2010 IEC 60335-2-2 IEC 60335-2-3 DIN EN 60335-2-3: 2002 IEC 60335-2-4 + 3 more
View Profile
DAkkS D-K-18255-01-00 Amberg, DE
Drehmoment 0,01 N·m Railway — traction effort and braking fo 0,1 N·m
View Profile
DAkkS D-K-21738-01-01 Köln, DE
- Gleichspannung Messgeräte > 330 mV > 3,3 V > 33 V > 330 V + 3 more
View Profile

DIAL

Active
DAkkS D-PL-17358-02-00 Lüdenscheid, DE
DIN 5032-1 DIN 5032-2 DIN 5032-4 DIN 5033-8 DIN 5036-3 + 3 more
View Profile

DIANOVIS

Active
DAkkS D-ML-21243-01-01 Gera, DE
Kleines Blutbild (maschinell) Differentialblutbild (maschinell) Thrombozyten Retikulozyten Natriumchlorid + 3 more
View Profile
DAkkS D-K-15034-01-01 Gevelsberg, DE
Gleichspannung 10 mV Quellen > 100 mV > 1 V > 10 V > 100 V + 3 more
View Profile
DAkkS D-PL-11125-01-00 Nürnberg, DE
ASTM C 1166 IEC 60512-16-7 ID168 IEC 60512-16-9 AK gegen Sc1-70 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturing Railway infrastructure operators Pantograph component suppliers Vehicle certification bodies

Related Standards

  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50317 Railway catenary — current collection quality measurement
  • IEC 60494-1 Railway overhead lines — pantograph heads

Other Test Methods

0 labs selected
Compare