EN 50206-2
Metro and Tram Pantograph Testing
This test evaluates the performance characteristics of pantographs designed for metro and tram systems operating at lower speeds with different catenary configurations than main line railways. It assesses mechanical robustness, contact stability, wear rates, and electrical properties specific to urban rail environments with frequent acceleration and braking cycles. Public transport operators and rolling stock manufacturers depend on this accreditation to ensure pantograph reliability in urban transit networks. Accredited testing validates product safety and performance in metropolitan electrified rail systems across Europe.
What it measures
- Contact force stability in urban operating conditions
- Mechanical endurance under frequent acceleration/deceleration
- Carbon strip or contact material wear rate
- Electrical contact quality and resistance stability
- Response to variable catenary tension
🇩🇪
DIN EN 50206-1
🇬🇧
BS EN 50206-1
🇫🇷
NF EN 50206-1
🇮🇹
UNI EN 50206-1
🇪🇸
UNE EN 50206-1
🇳🇱
NEN EN 50206-1
🇩🇪
DIN EN 50317
🇬🇧
BS EN 50317
🇫🇷
NF EN 50317
🇮🇹
UNI EN 50317
🇪🇸
UNE EN 50317
🇳🇱
NEN EN 50317
1,399
Accredited labs
17
Countries
Showing 426–450 of 1,399 labs
Furness Controls
Active
FLOW
Gas pressure (absolute)
Gas pressure (gauge)
DC CURRENT
TEMPERATURE
+ 3 more
G + B Kalibriertechnik
Active
Druck *
Absolutdruck Pabs
1 bar; 3 bar
Negativer und
positiver Überdruck
+ 3 more
G&L Consultancy
Active
(HSG 248) – 2021
M4 based on HSG 248
(PCM) based on HSG 248
M3 based on HSG 248
(HSG 264, 2012)
+ 1 more
G&M Procter
Active
based on ISO 11133:2014+Amd
dependent) based on BS EN
based on BS EN 12322:1999
G.B.N.S. Partnership
Active
(HSG 248) – 2021
(PCM) based on HSG 248
PRO02 based on HSG 248
GECI ESPAÑOLA
Active
3 mV U < 330 mV 0,33 V U < 3,3 V 3,3
0 mV U < 200 mV 200 mV U < 2 V 2 V
0 mV U 100 mV 0,1 V < U 1 V 1 V <
5 mV U 30 V
10 mV U < 33 mV 50 Hz f 1 kHz 1 kH
+ 3 more
GHMT
Active
DIN EN 50173-1
DIN EN 50173-2
DIN EN 50173-3
DIN EN 50173-4
DIN EN 50173-5
+ 3 more
DIN 51757
DIN EN ISO 12185
DIN EN ISO 3405
DIN EN 13016-1
DIN EN 237
+ 3 more
GMA-Werkstoffprüfung
Active
Koordinatenmesstechnik
Lasertracker*
0,5 m
1) In den CMC sind die erweiterten Messu
Bügelmessschrauben* 0 mm
+ 3 more
GMC-I Service
Active
- Gleichspannung
Messgeräte > 0,22 V
> 2,2 V
> 11 V
> 22 V
+ 3 more
GPR Gesundheits- und Pflegezentrum Rüsselsheim gemeinnützige GmbH Institut für Laboratoriumsmedizin
Active
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Erythrozytenzahl
Hämatokrit
Leucozytendifferenzierung
Leucozytenzahl
MCV
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
Innen- und Tiefenmaße
Wägewert/
+ 3 more
GRAVICAL
Active
Innen- und Tiefenmaße
Konventioneller
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
+ 1 more
GTM Testing and Metrology
Active
Vickers hardness test (ISO 6507)
Kraft
Kraftaufnehmer und
Sound power — survey method (ISO 3746)
0,2 MN
+ 3 more
9,8 L ≤ V ≤ 10,2 L (25 L/h ≤ Q ≤ 500 L/h
98 L ≤ V ≤ 104 L (250 L/h ≤ Q ≤ 5000 L/h
970 L ≤ V ≤ 1005 L (2500 L/h ≤ Q ≤ 20000
1305 L ≤ V ≤ 1350 L (5000 L/h ≤ Q ≤ 8000
2660 L ≤ V ≤ 2700 L (5000 L/h ≤ Q ≤ 1000
DIN 30655-1
DIN 30655-2
DIN 3590-1
DIN 3590-2
DIN 30652-2
+ 3 more
Anti-Müller-Hormon
Androstendion
CA 125
Cortisol
DHEA-S
+ 3 more
Azoospermie (AZF-Mikrodeletionen)
Fragiles X-Syndrom (FMR1)
Chorea Huntington (HTT)
Spinocerebelläre Ataxie Typ1
(ATXN1); Typ 2 (ATXN2); Typ 3
+ 3 more
Gerico Lab Srl
Active
ETSI EN 319 412
ETSI EN 319 401
ETSI EN 319 411-2
ETSI EN 319 411-1
Gerinnungszentrum Rhein-Ruhr
Active
Thrombozytenaggregation
Epinephrin-Ristocetin) nach
Verschlusszeitbestimmung
Kollagen / ADP, PFA-Kollagen
Epinephrin, PFA-P2Y)
+ 3 more
No matching labs found.