EN 50317

Railway Catenary Current Collection Quality

This standard defines measurement systems and procedures for evaluating current collection quality between pantograph and overhead catenary lines during train operation. It specifies methods for measuring contact force, arcing, electrical quality, and mechanical interaction to verify system performance in real operational conditions. Railway infrastructure managers and rolling stock operators use these measurements to assess electrification system health, validate pantograph performance, and optimize maintenance schedules. Accredited testing laboratories provide the reliable data necessary for safe, efficient railway operations and network diagnostics.

What it measures

  • Contact force during dynamic operation
  • Arcing occurrence and duration
  • Electrical voltage and current fluctuations
  • Pantograph contact strip wear patterns
  • Catenary geometry and tension variations
🇩🇪 DIN EN 50206-1 🇬🇧 BS EN 50206-1 🇫🇷 NF EN 50206-1 🇮🇹 UNI EN 50206-1 🇪🇸 UNE EN 50206-1 🇳🇱 NEN EN 50206-1 🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2
1,399 Accredited labs
17 Countries

Showing 226–250 of 1,399 labs

UKAS 0789 Great Dunmow, GB
Sound Calibrators FREQUENCY Microphones based: ½” & ¼” microphones @ 250 Hz + 3 more
View Profile
UKAS 1079 Gloucestershire, GB
BS ISO 488:2008, 2446:2008 and on BS 4401:Part 3:1970(1986) BS 696-2:1989 (superseded and BS ISO 6731:2010 ISO BS EN 3727-1:2002 + 3 more
View Profile
UKAS 4301 Llanishen, GB
Electrolytes in blood serum: Enzymes in blood serum: (Chlamydia pneumoniae, Mycoplasma urine: Hormones in blood serum: + 1 more
View Profile

Carl Zeiss

Active
DAkkS D-PL-12125-01-01 Oberkochen, DE
DIN EN 60601-1 IEC 60601-1 DIN EN 60601-1-1 IEC 60601-1-1 IEC 80601-2-77 + 3 more
View Profile
DAkkS D-K-21703-01-00 Oberkochen, DE
Carl Zeiss Industrielle ≤ 3818 mm Oberkochen, D 1) In den CMC sind die erweiterten Messu Carl Zeiss Industrielle ≤ 20 m Auswertesoftware Messvolumen mit + 3 more
View Profile
DAkkS D-K-15007-01-01 Oberkochen, DE
Parallelendmaße 50 mm DIN EN ISO 3650:1999 Thermischer Ausdeh- Maximale Dimension Bandbreite Höhe: 80 mm + 3 more
View Profile
DAkkS D-PL-12037-01-02 Jena, DE
DIN EN 61010-1 VDE 0411-1 IEC 61010-1 : 2010 DIN EN 60825-1 VDE 0837 + 3 more
View Profile
DAkkS D-K-12037-01-01 Jena, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 40 mm Parallelendmaße * ≥ 100 mm Strichmaßstäbe 0 mm + 3 more
View Profile
UKAS 27202 Paisley, GB
(HSG 264, 2012)
View Profile
UKAS 7914 Willsbridge, GB
5 of HSG 227 (2004)) (HSG 264, 2012)
View Profile
UKAS 1643 Chelmsford, GB
(cdt), Deletion an Pos 117 (HSG 248) – 2021 (PCM) based on HSG 248 BS 6068-4.12:1998 (withdrawn)
View Profile

CeGaT

Active
DAkkS D-ML-13206-01-01 Tübingen, DE
angeborener Chromosomensatz (Imbalancen im Genom, (Duplikationen/Del SNRPN-Region 15q11-13 UPD15 (UBE3A) SMN1; Spinale Muskelatrophie + 3 more
View Profile

Cenata

Active
DAkkS D-ML-21205-01-01 Tübingen, DE
Pränatales Screening auf Chromosomenstörungen (Trisomie 21, Trisomie 18, Trisomie 13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
View Profile
UKAS 0822 Southam, GB
Calibration of pressure Gas pressure (gauge) Gas Pressure (Differential) common mode pressure of 3.5 Hydraulic pressure (gauge) + 3 more
View Profile
DAkkS D-ML-13008-09-01 Berlin, DE
Whole genome sequencing (WGS: SNV, CNV/SV)
View Profile

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Chelab

Active
ACCREDIA 00051 Resana, IT
ISO 9308-1 ISO 7899-2 ISO 17410 ISO 16266 ISO 19250 + 3 more
View Profile
UKAS 6536 Leicester, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile
UKAS 9102 Bellshill, GB
(HSG 248) – 2021 SRV-002 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 0318 Derby, GB
Chronic progressive external Depth Internal Dial gauges and dial test Caliper + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
UKAS 0595 1 South Gyle Crescent, GB
simulation. parameters and ranges) digital and analogue
View Profile

Compli Group

Active
UKAS 4332 Poole, GB
DC CURRENT DC Resistance Oscilloscope Calibration DC VOLTAGE CAPACITANCE + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile

CoRFiLaC

Active
ACCREDIA 00285 Ragusa, IT
ISO 8968-1 DIN EN ISO 8968-1 ISO 3433:2008 DIN EN 14675 AOAC 991.14-1994 + 3 more
View Profile

No matching labs found.

Industries

Railway infrastructure management Railway operations and maintenance Catenary and OLE system designers Rolling stock operators Quality assurance and diagnostics

Related Standards

  • EN 50206-1 Railway pantographs — requirements for main line pantographs
  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods

0 labs selected
Compare