EN 50317
Railway Catenary Current Collection Quality
This standard defines measurement systems and procedures for evaluating current collection quality between pantograph and overhead catenary lines during train operation. It specifies methods for measuring contact force, arcing, electrical quality, and mechanical interaction to verify system performance in real operational conditions. Railway infrastructure managers and rolling stock operators use these measurements to assess electrification system health, validate pantograph performance, and optimize maintenance schedules. Accredited testing laboratories provide the reliable data necessary for safe, efficient railway operations and network diagnostics.
What it measures
- Contact force during dynamic operation
- Arcing occurrence and duration
- Electrical voltage and current fluctuations
- Pantograph contact strip wear patterns
- Catenary geometry and tension variations
๐ฉ๐ช
DIN EN 50206-1
๐ฌ๐ง
BS EN 50206-1
๐ซ๐ท
NF EN 50206-1
๐ฎ๐น
UNI EN 50206-1
๐ช๐ธ
UNE EN 50206-1
๐ณ๐ฑ
NEN EN 50206-1
๐ฉ๐ช
DIN EN 50206-2
๐ฌ๐ง
BS EN 50206-2
๐ซ๐ท
NF EN 50206-2
๐ฎ๐น
UNI EN 50206-2
๐ช๐ธ
UNE EN 50206-2
๐ณ๐ฑ
NEN EN 50206-2
1,632
Accredited labs
19
Countries
Showing 201โ225 of 1,632 labs
Bridgend Asbestos Services
Active
(HSG 248) โ 2021
P10.2 based on HSG 248
(PCM) based on HSG 248
British Engineering Services
Active
รNORM EN ISO 3452-1
BS 3923-1:1986(Withdrawn)
ASTM E165-23
BS 4124:1991(Withdrawn)
DIN EN 10228-3
+ 3 more
Based on ISO 10312:2019 and ISO
SOP 16 by XRD (ISO BS EN
IEC 60945
IEC 61162-1
IEC 61162-2
IEC 61162-450
IEC 61162-460
+ 3 more
Radioaktivitรคt 50 Bq/mยณ
Radon-222-
100 Bq/mยณ
tration in Luft
200 Bq/mยณ
+ 3 more
DIN EN ISO 2808
DIN EN ISO 3219-2
DIN EN ISO 3838
DIN EN 933-1
DIN EN 933-4
+ 3 more
Conformity assessment โ requirements for
Railway composite brake blocks โ require
0,2 kN
0,4 kN
100 kN
+ 3 more
Bundesministerium der Verteidigung Bundeswehrkrankenhaus Berlin Abteilung XVI Laboratoriumsmedizin
Active
NRBC-Normoblasten
Anteil unreifer Retikulozyten
Erythrozyten
DELTA-He
Leukozyten
+ 3 more
Blutungszeit PFA ADP
Blutungszeit PFA EPI
PFA-P2Y
Erythrozyten
Hรคmatokrit
+ 3 more
Leukozyten
Enteroaggregative E. coli
Legionellen
Staphylokokkus aureus
Salmonellen
+ 3 more
DIN ISO 17289
DIN EN ISO 10523
DIN EN 27888
NF X 31-615 (Uniquement
DIN EN 1337-6
DIN EN ISO 1421
DIN EN ISO 3377-1
DIN EN ISO 3377-2
DIN EN ISO 13934-1
+ 3 more
C G C Laboratory
Active
(HSG 248) โ 2021
(PCM) based on HSG 248
SOP 5, based on HSG 248
SOP 4, based on HSG 248
/ Messgerรคte
Radiometrie 100 ยตW/cmยฒ
stรคrkemessgerรคte
UV-A 365nm
Linearitรคt der
+ 3 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
Radiated emissions (CISPR 32)
verwendete Abkรผrzungen:
ETSI EN 301 489-1: V2.2.3
EN 61000-3-2 and EN 61000-3-3
IEC 61000-6-1
IEC 61000-4-4: 2012
1.4 Electrostatic Discharge EN 61000-4
+ 3 more
C.W.E. Services
Active
(HSG 264, 2012)
HSG 227 (2004))
Safety Executive guides HSG 264
(2012) and App 3 of HSG 227
(HSG 248) โ 2021
+ 3 more
CAL
Active
DIN 38402-A 11
DIN 38402-A 12
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-6 (A 15)
+ 3 more
DIN EN ISO 17294-2
DIN EN ISO 14403-2
DIN EN ISO 13395
VDE 414-9-11
DIN EN ISO 10304-1
+ 3 more
No matching labs found.