IEC 60494-2

Railway Pantograph Head Type 2 Dimensions

This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.

What it measures

  • Type 2 pantograph head contact width and profile geometry
  • Carbon or composite strip material composition and thickness
  • Contact surface hardness and wear resistance
  • Electrical conductivity and contact resistance
  • Mechanical deflection under typical operating forces
🇩🇪 DIN EN IEC 60494-1 🇬🇧 BS EN IEC 60494-1 🇫🇷 NF EN IEC 60494-1 🇮🇹 UNI EN IEC 60494-1 🇪🇸 UNE EN IEC 60494-1 🇳🇱 NEN EN IEC 60494-1 🇩🇪 DIN EN 50206-2 🇬🇧 BS EN 50206-2 🇫🇷 NF EN 50206-2 🇮🇹 UNI EN 50206-2 🇪🇸 UNE EN 50206-2 🇳🇱 NEN EN 50206-2
1,399 Accredited labs
17 Countries

Showing 26–50 of 800 labs

DAkkS D-K-17447-01-01 Essen, DE
Conformity assessment — requirements for Druckkraftrichtung Drehmoment 0,01 N∙m Drehmomentaufnehmer * Drehmomentmessgeräte * + 3 more
View Profile
DAkkS D-K-21102-01-00 Donaueschingen, DE
Temperaturmessgrößen Temperatursensoren in Railway bogies — wheelsets and bogies st Railway braking — urban guided transport Railway vehicle body structural requirem + 3 more
View Profile
DAkkS D-PL-19253-01-00 Hamburg, DE
DIN 52186 ISO 21527-1 DIN EN ISO 527-3 IEC 61924-2 DIN EN 62233 + 3 more
View Profile
DAkkS D-PL-19572-01-01 Bochum, DE
DIN EN ISO 6246 DIN 53160-1 DIN EN ISO 22854 (LBLS) (OMIM 611105) (c.228- DIN EN 13016-1 + 3 more
View Profile
DAkkS D-K-15206-01-00 Oberdischingen, DE
Sound intensity — scanning method (ISO 9 Messgeräte für die Härteskale Shore A* Analoge Anzeige Railway freight wagon brake system requi + 3 more
View Profile
DAkkS D-K-20341-02-00 Bad Nenndorf, DE
Temperaturanzeigegeräte –100 °C bis - Direktanzeigende Thermometer - Thermopaare, Thermoelemente verwendete Abkürzungen:
View Profile
DAkkS D-ML-19082-01-00 Oberschleißheim, DE
Salmonella spp. Antikörper) Treponema pallidum (Lues) Thrombozytäre Antikörper dysenteriae), Vibrio cholerae + 3 more
View Profile
DAkkS D-ML-13090-01-00 Hamburg, DE
Echinococcus granulosus Echinococcus multilocularis Paragonimus uterobilateralis Ascaris lumbricoides (IgG) Brucella spp. (IgG, IgM) + 3 more
View Profile
DAkkS D-K-15017-01-00 Frankfurt, DE
Vickers hardness test (ISO 6507) Temperatur * Temperaturmessgrößen −35 °C Railway braking — urban guided transport Temperatur −40 °C + 3 more
View Profile
DAkkS D-ML-13452-02-00 Berlin, DE
Hämoglobin Differentialblutbild Erythrozyten Großes Blutbild Kleines Blutbild + 3 more
View Profile
DAkkS D-ML-13452-10-00 Freiburg, DE
Okkultes Blut Großes Blutbild Kleines Blutbild Retikulozyten Thrombozyten + 3 more
View Profile
DAkkS D-ML-13452-01-01 Ingelheim, DE
2C-B 2C-I 3-Hydroxy-Bromazepam 5-Hydroxyindolessigsäure 6-Acetylcodein + 3 more
View Profile
DAkkS D-ML-13452-05-00 Jena, DE
Zelldifferenzierung Erythrozyten Großes Blutbild Hämoglobin Kleines Blutbild + 3 more
View Profile
DAkkS D-ML-13452-07-00 Mainz, DE
Hämoglobin (immunologisch) CA 125 CA 15-3 CA 19-9 CA 72-4 + 3 more
View Profile
DAkkS D-ML-13452-06-00 Moers, DE
Hämoglobin Natriumchlorid Kalium Natrium Eiweißelektrophorese: Albumin, Alpha-1-G + 3 more
View Profile
DAkkS D-ML-13322-01-00 Karlsruhe, DE
10-OH-Carbazepin 11-Deoxycortisol 17-OH-Progesteron 21-Deoxycortisol 25-OH Vitamin D2 + 3 more
View Profile
DAkkS D-ML-19774-01-01 Gießen, DE
Thrombozytenfunktion 5-Hydroxyindolessigsäure Adrenalin Amiodaron, Desmethylamiodaron Carbohydrate-deficient + 3 more
View Profile
DAkkS D-ML-13031-01-01 St. Ingbert, DE
Lamotrigin Metanephrine, Normetanephrine Erythrozyten Aripiprazol Lymphozyten + 3 more
View Profile

Bizerba SE &

Active
DAkkS D-PL-15018-01-00 Balingen, DE
IEC 61000-4-2: 2008 IEC 61000-4-3: 2006 IEC 61000-4-4: 2012 IEC 61000-4-5: 2005 IEC 61000-4-6: 2013 + 3 more
View Profile

Blower Door

Active
DAkkS D-K-19788-01-00 Springe-Eldagsen, DE
Positiver und negativer verwendete Abkürzungen: DKD-R
View Profile
DAkkS D-PL-18812-01-02 Bremen, DE
DIN EN ISO 2418 DIN EN 61340-4-4 DIN CEN ISO/TS 16179 DIN EN ISO 14362-1 DIN EN ISO 14362-3 + 3 more
View Profile
DAkkS D-PL-12084-01-00 Hamburg, DE
IEC 60945 IEC 61162-1 IEC 61162-2 IEC 61162-450 IEC 61162-460 + 3 more
View Profile
DAkkS D-K-15063-01-00 Berlin, DE
Radioaktivität 50 Bq/m³ Radon-222- 100 Bq/m³ tration in Luft 200 Bq/m³ + 3 more
View Profile
DAkkS D-PL-11075-01-01 Berlin, DE
DIN EN ISO 2808 DIN EN ISO 3219-2 DIN EN ISO 3838 DIN EN 933-1 DIN EN 933-4 + 3 more
View Profile
DAkkS D-K-11075-08-00 Berlin, DE
Conformity assessment — requirements for Railway composite brake blocks — require 0,2 kN 0,4 kN 100 kN + 3 more
View Profile

No matching labs found.

Industries

Metro and tram pantograph head manufacturers Urban transit rolling stock manufacturers Contact material and strip suppliers Metro system operators and maintainers

Related Standards

  • IEC 60494-1 Railway overhead lines — pantograph heads
  • EN 50206-2 Railway pantographs — requirements for metro and tram pantographs
  • EN 50119 Railway applications — fixed installations — electric traction overhead contact lines

Other Test Methods

0 labs selected
Compare