IEC 60494-2
Railway Pantograph Head Type 2 Dimensions
This standard specifies dimensional and material requirements for Type 2 pantograph head contacts designed for metropolitan and urban railway systems with different electrical and mechanical demands than main line networks. It defines standardized contact strip profiles to ensure compatibility with metro and tram catenary systems and interoperability across urban transit networks. Manufacturers and transit operators require accreditation of this test to ensure product compliance and safe, reliable operation in metropolitan electrified rail systems. Standardized Type 2 heads reduce compatibility issues and maintenance costs across metro and tram networks.
What it measures
- Type 2 pantograph head contact width and profile geometry
- Carbon or composite strip material composition and thickness
- Contact surface hardness and wear resistance
- Electrical conductivity and contact resistance
- Mechanical deflection under typical operating forces
🇩🇪
DIN EN IEC 60494-1
🇬🇧
BS EN IEC 60494-1
🇫🇷
NF EN IEC 60494-1
🇮🇹
UNI EN IEC 60494-1
🇪🇸
UNE EN IEC 60494-1
🇳🇱
NEN EN IEC 60494-1
🇩🇪
DIN EN 50206-2
🇬🇧
BS EN 50206-2
🇫🇷
NF EN 50206-2
🇮🇹
UNI EN 50206-2
🇪🇸
UNE EN 50206-2
🇳🇱
NEN EN 50206-2
1,632
Accredited labs
19
Countries
Showing 476–500 of 875 labs
WBC (Leukozyten)
RBC (Erythrocyten)
HGB (Hb)
HCT (Hk)
PLT (Thrombozyten)
+ 3 more
Chromosomensatz (angeboren)
Chromosomensatz (erworben)
Adrenogenitales Syndrom
Angelman-Syndrom (15q11-Region, UBE3A)
Mikrodeletionen; AZFa-c)
+ 3 more
HbA1c
Basophile, automatisch
Eosinophile, automatisch
Erythrozyten, automatisch
Leukozyten, automatisch
+ 3 more
HbA1c
Hämatokrit
Hämoglobin
Leukozyten
Thrombozyten
+ 3 more
HbA1c
Blutbild, groß (Blutbild klein
Hämoglobin, Hämatokrit, MCH, MCHC)
Retikulozyten
Thrombozyten
+ 3 more
Leukozyten
Erythrozyten
Thrombozyten
Hämatokrit
MCV
+ 3 more
Obligat anaerobe Bakterien
Grampositive aerobe und
anaerobe Kokken
Enterokokken
Mikrokokken
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Melutec Metrology
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 100 mm
Messschieber für Außen-, 0 mm
+ 3 more
Metrolution
Active
Metrosoft CM, Software einer Raumdiagona
AG, Chur, CH ≤ 3333 mm
Oberkochen, D
GmbH, Wetzlar, D
AG, Chur, CH ≤ 7500 mm
Mettler-Toledo
Active
Flüssigkeitsvolumen *
Kolbenhubpipetten
Manuell betätigte
spritzen
Mehrfachdispenser
+ 3 more
MeßTechnikNord
Suspended
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
MeßTechnikNord
Active
- Gleichspannung
Messverstärker > 120 mV
> 1 V
> 12 V
> 1000 V
+ 3 more
Minebea Intec Bovenden
Active
Konventioneller
Wägewert/
Massenormale
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
+ 3 more
Bacillus cereus Toxin
Clostridium perfringens
Salmonella spp.
Shigella spp.
Staphylococcus aureus Toxin
+ 3 more
Mitutoyo Deutschland
Active
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 10 mm
Parallelendmaße > 100 mm
+ 3 more
Mobiler Kalibrierdienst Fini
Active
Gleichspannung 3 mV
Messgeräte 10 mV
> 100 mV
> 220 mV
> 11 V
+ 3 more
Temperatur 50 °C
Railway brake handbooks (UIC 547)
1) In den CMC sind die erweiterten Messu
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
Mühlenkreiskliniken AöR Institut für Laboratoriumsmedizin, Transfusionsmedizin und Mikrobiologie
Active
Differentialblutbild
Kleines Blutbild (maschinell)
Thrombozyten
Unreife Thrombozyten (IPF)
Urinsediment (maschinell)
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN ISO 8297
DIN EN ISO 12354-4
+ 3 more
München Klinik gGmbH Medizet - Institut für Laboratoriumsmedizin und medizinische Mikrobiologie
Active
Hämoglobin A1c
Hämoglobin-Differenzierung
Erythrozyten
Basophile Granolozyten
Eosinophile Granulozyten
+ 3 more
NATEC Sensors
Active
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
Gleichspannung U
(Simulation des Signals
generators)
+ 3 more
NEMKO
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
Narda Safety Test Solutions
Active
Elektrische Feldstärke /
2 V/m
2,5 V/m
1 V/m
Magnetische Feldstärke /
+ 3 more
No matching labs found.