IEC 62846

Railway Pantograph Interaction with Overhead Contact Line

This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.

What it measures

  • Contact force between pantograph head and overhead line
  • Arcing and electrical discontinuities during contact
  • Pantograph head wear rate and material loss
  • Dynamic lift and pressure stability at various speeds
  • Compatibility with different catenary wire geometries
🇩🇪 DIN EN 50206 🇬🇧 BS EN 50206 🇫🇷 NF EN 50206 🇮🇹 UNI EN 50206 🇪🇸 UNE EN 50206 🇳🇱 NEN EN 50206 🇩🇪 DIN EN 50367 🇬🇧 BS EN 50367 🇫🇷 NF EN 50367 🇮🇹 UNI EN 50367 🇪🇸 UNE EN 50367 🇳🇱 NEN EN 50367
1,399 Accredited labs
17 Countries

Showing 276–300 of 800 labs

DAkkS D-ML-13295-01-01 München, DE
Kleines Blutbild Differentialblutbild maschinell C-reaktives Protein (CRP) Differentialblutbild manuell Urinstatus + 3 more
View Profile
DAkkS D-ML-13295-03-00 München, DE
17-OH-Progesteron ACTH Androstendion Aldosteron Anti-TG Antikörper + 3 more
View Profile
DAkkS D-ML-13421-01-00 Ludwigshafen, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu CDT Ampicilin Cefepim + 3 more
View Profile
DAkkS D-ML-13136-01-01 Augsburg, DE
Rhythmusstörungen (ABCC9, AKAP9, ANK2,TT MSH2, MSH6, MUTYH, PMS2, PTEN, RAD51C, R Familiärer Brust- und Eierstockkrebs MSH2, MSH6, EPCAM ); SNV, CNV Birt-Hogg-Dubé-Syndrom (FLCN + 3 more
View Profile
DAkkS D-ML-13400-01-00 Groß Grönau, DE
AMA M2-3E IgG Anti-CCP (Cyclische Citrullin Antikörper) IgG Anti-dsDNS-NCX IgG Anti- Transglutaminase + 3 more
View Profile
DAkkS D-K-17518-01-01 Remscheid, DE
abweichungen Metrosoft CM und Messvolumen Metrosoft QUARTIS, mit einer Software der Fa. WENZEL Raumdiagonale Metromec Chur, CH von ≤ 4666 mm
View Profile
DAkkS D-K-15098-01-01 Leonberg, DE
Software von WENZEL einer Raumdiagonalen Messprojektoren einer Raumdiagonalen Koordinatenmessgeräte geräte mit einem Messmikroskope ≤ 600 mm Auswertesoftware Messvolumen mit + 2 more
View Profile
DAkkS D-K-15077-01-00 Aschaffenburg, DE
Parallelendmaße 0,5 mm bis DIN EN ISO 3650:1999 Parallelendmaße aus 0,5 mm bis Keramik oder Wolframkarbid nach + 3 more
View Profile
DAkkS D-K-22877-01-01 Eschweiler, DE
(ein- und mehrgängige zylindrische Außen- und geradlinigen Flanken und symmetrischem Profil sowie positiven Flankenwinkeln) + 3 more
View Profile
DAkkS D-ML-13173-01-00 Bad Oeynhausen, DE
Thrombozytenfunktion Amiodaron/Desethylamiodaron Cotinin Cyclosporin A Everolimus + 3 more
View Profile
DAkkS D-ML-21357-01-00 Heppenheim, DE
Albumin Alkohol ALP Anti-Faktor Xa (Fragmin) AT3 + 3 more
View Profile
DAkkS D-K-15009-01-01 Leipzig, DE
Eindringkörper für 75° Sound system equipment — speech transmis Länge der Schnittlinien * Vergrößerungsnormale Abflachung bis 300 + 3 more
View Profile
DAkkS D-K-15082-01-00 Hamburg, DE
Durchfluss von Gasen 17 mL/s transferstandards Strömungswiderstand 5 mL/min 15,0 mL/min Laminar Flow Elemente 17 mL/min + 3 more
View Profile
DAkkS D-K-17059-02-01 Dresden, DE
Messschieber für Außen-, 0 mm Innen- und Tiefenmaße > 300 mm Tiefenmessschieber 0 mm Höhenmessschieber 0 mm + 3 more
View Profile
DAkkS D-PL-19182-02-01 Quakenbrück, DE
DIN EN ISO 105-B02 DIN EN ISO 105-006 DIN EN ISO 105-008 DIN EN ISO 105-D01 DIN EN ISO 105-E01 + 3 more
View Profile
DAkkS D-ML-13087-01-00 Schüttorf, DE
10-Hydroxycarbazepin (MHD) Amiodaron, Desmethylamiodaron Clozapin, Norclozapin Cyclosporin A Amiodaron, Desethylamiodaron + 3 more
View Profile
DAkkS D-ML-13087-02-00 Leer, DE
HbA1c Basophile Eosinophile Erythrozyten Hämatokrit + 3 more
View Profile
DAkkS D-ML-17171-01-01 Baden-Baden, DE
HbA1c HCG qualitativ Erythrozyten Granulozyten basophil Granulozyten eosinophil + 3 more
View Profile
DAkkS D-ML-20249-01-00 Braunschweig, DE
HbA1c Retikulozyten Leukozyten Kleines Blutbild Großes Blutbild = + 3 more
View Profile
DAkkS D-ML-13183-01-00 Bremen, DE
HbA1c Zellzahl Blutbild groß Blutbild klein Retikulozyten + 3 more
View Profile
DAkkS D-ML-13107-01-00 Geesthacht, DE
Thrombozytenfunktionstest 2-Desoxypipradol (2-DPMP) 2-oxo-3-hydroxy-LSD 3.4-DMMC 3-Fluormethcathinon + 3 more
View Profile
DAkkS D-ML-13109-01-01 Hannover, DE
HbA1c Basophile Granulozyten Eosinophile Granulozyten Erythrozyten Hämatokrit + 3 more
View Profile
DAkkS D-ML-13319-02-01 Neuruppin, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu HbA1c Basophile Eosinophile + 3 more
View Profile
DAkkS D-ML-13132-01-00 Flintbek, DE
HbA1c Retikulozyten Leukozyten Neutrophile Granulozyten Lymphozyten + 3 more
View Profile
DAkkS D-ML-13194-01-01 Recklinghausen, DE
Blutsenkung Benzol Ethylbenzol Aceton, Isopropanol, Methanol Ethanol + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway infrastructure operators Public transport authorities Catenary system suppliers Rail maintenance and depot operators

Related Standards

  • EN 50206 Railway applications - Pantographs - Rules for testing and validation
  • EN 50367 Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead line
  • IEC 61853 Railway applications - Testing and measurement of pantograph and overhead line interaction

Other Test Methods

0 labs selected
Compare