EN 12299
Measurement and Evaluation of Railway Ride Comfort
EN 12299 establishes standardised methods for measuring and evaluating passenger ride comfort in railway vehicles through vibration analysis. The standard defines vibration indices including Nmv (main index), NVA (vertical), and NVD (lateral) to objectively quantify passenger comfort levels during train operation. This test is essential for railway manufacturers and operators to ensure compliance with comfort standards, validate new vehicle designs, and support passenger satisfaction assessments. Accreditation guarantees correct instrumentation setup, accurate measurement procedures, and proper calculation of comfort indices according to European rail requirements.
What it measures
- Main ride comfort index (Nmv)
- Vertical vibration discomfort (NVA)
- Lateral vibration discomfort (NVD)
- Frequency-weighted acceleration
- Overall comfort rating
🇩🇪
DIN EN ISO 2631-1
🇬🇧
BS EN ISO 2631-1
🇫🇷
NF EN ISO 2631-1
🇮🇹
UNI EN ISO 2631-1
🇪🇸
UNE EN ISO 2631-1
🇳🇱
NEN EN ISO 2631-1
🇩🇪
DIN EN 14363
🇬🇧
BS EN 14363
🇫🇷
NF EN 14363
🇮🇹
UNI EN 14363
🇪🇸
UNE EN 14363
🇳🇱
NEN EN 14363
1,632
Accredited labs
19
Countries
Showing 276–300 of 1,632 labs
CSTB - Grenoble
Active
DIN EN 1279-2
DIN EN 1279-5
DIN EN 12094-10
EN 1279-6 – Méthode de référence
DIN EN 14449
+ 3 more
CTK-Poliklinik
Active
Oligosaccharide
Chromatographie (Gaschromatograpie
Cannabinoide (THC-COOH)
Amphetamine
Opiate
+ 3 more
DIN EN ISO 13934-1
DIN EN ISO 13935-2
DIN EN ISO 13937-2
DIN EN ISO 13937-3
DIN EN 14682
+ 3 more
CTS Clima Temperatur Systeme
Active
Vickers hardness test (ISO 6507)
Temperaturmessgrößen –70 °C
Railway braking — urban guided transport
Thermometer mit > –40 °C
Widerstandssensor *
+ 3 more
DC VOLTAGE
DC Resistance
DC CURRENT
AC Current Generation
Generation (continued)
+ 3 more
Campbell Associates
Active
Sound Calibrators
FREQUENCY
Microphones
based:
½” & ¼” microphones @ 250 Hz
+ 3 more
BS ISO 488:2008, 2446:2008 and
on BS 4401:Part 3:1970(1986)
BS 696-2:1989 (superseded and
BS ISO 6731:2010
ISO BS EN 3727-1:2002
+ 3 more
Electrolytes in blood serum:
Enzymes in blood serum:
(Chlamydia pneumoniae, Mycoplasma
urine:
Hormones in blood serum:
+ 1 more
Carl Zeiss
Active
DIN EN 60601-1
IEC 60601-1
DIN EN 60601-1-1
IEC 60601-1-1
IEC 80601-2-77
+ 3 more
Carl Zeiss IQS Deutschland
Active
Carl Zeiss Industrielle ≤ 3818 mm
Oberkochen, D
1) In den CMC sind die erweiterten Messu
Carl Zeiss Industrielle ≤ 20 m
Auswertesoftware Messvolumen mit
+ 3 more
Parallelendmaße 50 mm
DIN EN ISO 3650:1999
Thermischer Ausdeh- Maximale Dimension
Bandbreite
Höhe: 80 mm
+ 3 more
Carl Zeiss Jena
Active
DIN EN 61010-1
VDE 0411-1
IEC 61010-1 : 2010
DIN EN 60825-1
VDE 0837
+ 3 more
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße * 40 mm
Parallelendmaße * ≥ 100 mm
Strichmaßstäbe 0 mm
+ 3 more
Cavendish Laboratories
Active
(cdt), Deletion an Pos 117
(HSG 248) – 2021
(PCM) based on HSG 248
BS 6068-4.12:1998 (withdrawn)
CeGaT
Active
angeborener Chromosomensatz
(Imbalancen im Genom, (Duplikationen/Del
SNRPN-Region 15q11-13 UPD15
(UBE3A)
SMN1; Spinale Muskelatrophie
+ 3 more
Cenata
Active
Pränatales Screening auf
Chromosomenstörungen
(Trisomie 21, Trisomie 18, Trisomie
13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
Chamois Metrology
Active
Calibration of pressure
Gas pressure (gauge)
Gas Pressure (Differential)
common mode pressure of 3.5
Hydraulic pressure (gauge)
+ 3 more
Whole genome sequencing (WGS:
SNV, CNV/SV)
Thyreoidea stimulierendes
(TSH)
17-α-OH-Progesteron
(17-OH-P)
Immunreaktives Trypsin
+ 3 more
Liquid-in-glass thermometers
ASTM D4052 (Digital density
CheckImmune
Active
Leukozytenzahl
B-Zellzahl (Immunstatus
Rezeptor-Besatz
HLA-DR
Leukozytensubpopulationen
+ 3 more
DIN 38402-A 13
DIN ISO 5667-5 (A 14)
DIN 38402-A 30
DIN 19643-1
ISO 5667-11
+ 3 more
No matching labs found.