UIC 518
Testing and Approval of Railway Vehicle Running Behaviour
UIC 518 is the International Union of Railways standard that specifies dynamic testing requirements for acceptance of railway vehicles based on running behaviour criteria. This standard, which served as the basis for the later EN 14363, defines measurements and limits for vehicle response to track irregularities, lateral dynamics, and operational safety across varying track conditions. It is historically significant in European rail certification and remains in use for certain vehicle classes and retrofit assessments. Accreditation for UIC 518 testing ensures proper measurement methodology and comparison against established international railway acceptance criteria.
What it measures
- Lateral acceleration response
- Wheel load variation under dynamic conditions
- Vehicle body acceleration and displacement
- Derailment coefficient assessment
- Running safety indices
🇩🇪
DIN EN 14363
🇬🇧
BS EN 14363
🇫🇷
NF EN 14363
🇮🇹
UNI EN 14363
🇪🇸
UNE EN 14363
🇳🇱
NEN EN 14363
🇩🇪
DIN EN 12299
🇬🇧
BS EN 12299
🇫🇷
NF EN 12299
🇮🇹
UNI EN 12299
🇪🇸
UNE EN 12299
🇳🇱
NEN EN 12299
1,632
Accredited labs
19
Countries
Showing 1,601–1,625 of 1,632 labs
biovis Diagnostik MVZ
Active
Lysozym
= Sexualhormon bindendes
Prolaktin
Freies Thyroxin 4 (FT4)
Beta-Defensin 2
+ 3 more
duagon Germany
Active
IEC 61000-6-1
IEC 61000-6-2: 2005
DIN EN 50155
VDE 0115-200
DIN EN 50121-3-2
+ 3 more
enveon
Active
VDE 0468-2-1
IEC 60068-2-1
VDE 0468-2-2
IEC 60068-2-2
DIN EN 60068-2-14
+ 3 more
Hochspannung
- Wechselspannung
Bereiche
Rechteckspannung
Amplitudenparameter
+ 3 more
eumetron
Active
− Durchmesser
− Parallelendmaße
− Formabweichung
− Strichmaße, Abstände
− Virtuelle Koordinatenmessgeräte
+ 3 more
eurofins Umwelt West
Active
DIN 19698-1
DIN 19698-2
DIN ISO 11464
DIN EN ISO 54321
DIN EN 12457-4
+ 3 more
halstrup-walcher
Active
Positiver und negativer
Positiver Überdruck p e
1) In den CMC sind die erweiterten Messu
i2 FAST
Active
BS 4401-1:1998 Using
N008-1 based on BS EN
ISO 12966-4 2015
N008-2 based on BS EN
N011 based on BS 4401-9:1975 and BS 770-
+ 3 more
iLF Magdeburg
Active
DIN EN ISO 9117-3
DIN EN ISO 9117-5
DIN EN ISO 1463
DIN EN ISO 2808
DIN EN ISO 2178
+ 3 more
Taupunkttemperatur
–0,91 bar bis
Positiver und negativer
Überdruck p *)
(ein- oder mehrgängige
+ 3 more
ifp-labs UK West Yorkshire
Active
on BS 4401:Part 3:1970(1986)
ISO 12966-1:2014 and
ISO 12966-4
CH 4026 based on BS 5766:Part
CH 4001 based on BS EN 12014-
+ 3 more
ift Rosenheim
Active
ASTM E 330/E 330M
ASTM E 283/E283M
DIN 4103-1
DIN 68706-1
UNE-EN 12211
+ 3 more
DIN EN ISO 5667-1 (A 4)
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-3 (A 21)
DIN EN ISO 19458 (K 19)
DIN 19643-1
+ 3 more
Taupunkttemperatur
fixpunktzellen
Railway braking — urban guided transport
Railway vehicle body structural requirem
SPRT-Sensor
+ 3 more
Absolutdruck p
abs
> 0,8 bar
> 1,2 bar
> 20 bar
+ 3 more
iocto
Active
Taupunkttemperatur
direktanzeigende −45 °C
Railway vehicle body structural requirem
Widerstandssensor
direktanzeigende > 200 °C
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten
+ 3 more
Großes Blutbild
TSH
Immunglobulin E
25-OH-Vitamin D
Vitamin B12
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten (Zellzahl)
+ 3 more
qbig
Active
Durchflussmess- 13 m³/h
- Hochspannungsmessgrößen
> 25 m³/h
Volumendurchfluss
> 40 m³/h
+ 3 more
Absolutdruck
10 hPa
Relativdruck
−1 000 hPa
Durchfluss von Gasen
+ 3 more
steep GmbH EMV-Zentrum
Active
DIN EN 55016-1-4
VDE 0877-16-1-4
DIN EN 55016-2-1
VDE 0877-16-2-1
DIN EN 55016-2-2
+ 3 more
No matching labs found.