ISO 13373-1

Machinery Vibration Condition Monitoring

ISO 13373-1 establishes general procedures for vibration-based condition monitoring and diagnostics of machines to detect developing faults and assess operational health. This standard defines measurement strategies, signal processing methods, and diagnostic logic applicable to diverse machine populations in industrial and operational environments. Maintenance departments, predictive maintenance service providers, and asset management teams use this methodology to optimise equipment uptime and plan cost-effective interventions. Accreditation ensures technically sound and reproducible monitoring data that supports evidence-based maintenance decisions and equipment reliability improvement.

What it measures

  • Vibration amplitude and frequency content across machine operating range
  • Broadband and narrowband vibration signatures
  • Trend progression and rate of change
  • Fault-specific frequencies and harmonics
  • Machine health status classification
๐Ÿ‡ฉ๐Ÿ‡ช DIN EN ISO 13373-2 ๐Ÿ‡ฌ๐Ÿ‡ง BS EN ISO 13373-2 ๐Ÿ‡ซ๐Ÿ‡ท NF EN ISO 13373-2 ๐Ÿ‡ฎ๐Ÿ‡น UNI EN ISO 13373-2 ๐Ÿ‡ช๐Ÿ‡ธ UNE EN ISO 13373-2 ๐Ÿ‡ณ๐Ÿ‡ฑ NEN EN ISO 13373-2 ๐Ÿ‡ฉ๐Ÿ‡ช DIN EN ISO 10816-1 ๐Ÿ‡ฌ๐Ÿ‡ง BS EN ISO 10816-1 ๐Ÿ‡ซ๐Ÿ‡ท NF EN ISO 10816-1 ๐Ÿ‡ฎ๐Ÿ‡น UNI EN ISO 10816-1 ๐Ÿ‡ช๐Ÿ‡ธ UNE EN ISO 10816-1 ๐Ÿ‡ณ๐Ÿ‡ฑ NEN EN ISO 10816-1
1,591 Accredited labs
17 Countries

Showing 151โ€“175 of 342 labs

UKAS 9875 Benfleet, GB
(HSG 248) โ€“ 2021 (PCM) based on HSG 248
View Profile
UKAS 2671 Castle Donington, GB
(HSG 248) โ€“ 2021 (PCM) based on HSG 248 DOC/002 based on HSG 248
View Profile
UKAS 4155 Sunderland, GB
5 of HSG 227 (2004) (HSG 264, 2012)
View Profile

Fugro GB

Active
UKAS 0919 Wallingford, GB
BS 1377: Part 2: 1990 BS 1377-3:2018 + A1:2021 ASTM D4186-12: 2020 ASTM D5334-22 ASTM D2216-19 + 3 more
View Profile
UKAS 10287 Chelmsford, GB
(HSG 264, 2012)
View Profile
UKAS 0580 Bexhill, GB
FLOW Gas pressure (absolute) Gas pressure (gauge) DC CURRENT TEMPERATURE + 3 more
View Profile
UKAS 2083 Wellington, GB
(HSG 248) โ€“ 2021 M4 based on HSG 248 (PCM) based on HSG 248 M3 based on HSG 248 (HSG 264, 2012) + 1 more
View Profile

G&M Procter

Active
UKAS 2727 Perth, GB
based on ISO 11133:2014+Amd dependent) based on BS EN based on BS EN 12322:1999
View Profile
UKAS 4037 Welwyn Garden City, GB
(HSG 248) โ€“ 2021 (PCM) based on HSG 248 PRO02 based on HSG 248
View Profile
UKAS 1278 Glasgow, GB
(HSG 248) โ€“ 2021 staining based on HSG 248 F2011 (BS 696:Part 2:1989) F0131 (BS 1741:10-1:1989) using F0008 (BS 696:Part 2:1989) using + 3 more
View Profile

Glenair UK

Active
UKAS 29564 Mansfield, GB
IEC 60068-2-14 IEC 60068-2-30 IEC 60068-2-2 IEC 60068-2-64 IEC 60068-2-1 + 3 more
View Profile
UKAS 7751 Sawbridgeworth, GB
(HSG 264, 2012)
View Profile
UKAS 9528 Stevenage, GB
Appendix 5 of HSG 227 (2004) (HSG 264, 2012)
View Profile
UKAS 2735 Portsmouth, GB
(HSG 248) โ€“ 2021 (PCM) based on HSG 248
View Profile
UKAS 0363 Portsmouth, GB
HSG 227 (2004)) (HSG 264, 2012) HSG 264 (2012) and Appx. 3 of Appendix 5 of HSG 227 (2004))
View Profile
UKAS 4026 Meopham, GB
(HSG 248) โ€“ 2021 (PCM) based on HSG 248 (HSG 264, 2012)
View Profile

HORIBA MIRA

Active
UKAS 1105 Nuneaton, GB
IEC/CISPR 25 DIN EN 55025: 2018 ISO 7637-2 ISO 11451-1 IEC/CISPR 12 + 3 more
View Profile
UKAS 0642 Ross-on-Wye, GB
(HSG 248) โ€“ 2021 M003 based on HSG 248 (PCM) based on HSG 248 M002based on HSG 248 HSG 227 (2004)) + 2 more
View Profile
UKAS 0024 Southsea, GB
(HSG 248) - 2021 ASB/SOP/OM8 based on HSG 248 ASB/SOP/OM6 based on HSG 248 DIN EN 12697-11 on BS 4401:Part 3:1970(1986) + 3 more
View Profile
UKAS 8452 Manchester, GB
BS 2790 - Specification for the design a BS 1113 - Specification for the design a BS EN 13480 Parts 1 to 8 - Metallic EN 13445 โ€“ Parts 1 to 10 Unfired pressur BS EN ISO 15614 and ASME IX + 3 more
View Profile
UKAS 4659 Newry, GB
(HSG 264, 2012) and Appx. 3 of HSG 227 (2004)) Executive guides HSG 264 (2012)
View Profile
UKAS 9868 Daventry, GB
DIN EN 1026 DIN EN 12046-2 BS 6375-1:2015 + A1:2016 and the DIN EN 1027 DIN EN 1629 + 3 more
View Profile

Hi Gain

Active
UKAS 4670 Andover, GB
MIL-STD-883G METHOD 3015.7 MIL-STD-883H METHOD 3015.8 MIL-STD-883J METHOD 3015.9
View Profile
UKAS 24561 Hertford, GB
(HSG 264, 2012)
View Profile

Horiba MIRA

Active
UKAS 2654 Basildon, GB
IEC 60068-2-14 IEC 60068-2-1 DIN EN 60068-2-14 IEC 60068-2-2 DIN EN IEC 60068-2-38 + 3 more
View Profile

No matching labs found.

Industries

Predictive maintenance services Manufacturing and process control Rotating machinery operations Thermal and hydro power plants Asset management and facility operations

Related Standards

  • ISO 13373-2 Condition monitoring and diagnostics of machinesโ€”Vibration condition monitoringโ€”Part 2: Guidance on the interpretation of vibration diagnostics
  • ISO 10816-1 Mechanical vibrationโ€”Evaluation of machine vibration by measurements on non-rotating partsโ€”Part 1: General guidelines
  • ISO 20816-1 Mechanical vibrationโ€”Measurement and evaluation of vibration of rotating machineryโ€”Part 1: General guidelines

Other Test Methods

0 labs selected
Compare