ISO 5349-1

Hand-Arm Vibration Measurement & Evaluation

ISO 5349-1 specifies methods for measuring and evaluating human exposure to vibration transmitted through the hands and arms during operation of hand-held or hand-guided tools and machinery. This test quantifies vibration acceleration in three orthogonal directions to assess occupational health risks including hand-arm vibration syndrome (HAVS) and vascular disorders. Employers, occupational health services, tool manufacturers, and regulatory authorities require this testing to comply with EU and national vibration exposure directives and to protect worker health. Accreditation ensures consistent measurement methodology, proper instrumentation calibration, and correct application of exposure action and limit values. Valid hand-arm vibration data is essential for workplace risk assessment and control strategy development.

What it measures

  • Vibration acceleration in X, Y, Z axes
  • Frequency-weighted acceleration magnitude
  • Daily vibration exposure (A(8))
  • Peak vibration values
  • Exposure uncertainty and measurement variability
🇩🇪 DIN EN ISO 5349-2 🇬🇧 BS EN ISO 5349-2 🇫🇷 NF EN ISO 5349-2 🇮🇹 UNI EN ISO 5349-2 🇪🇸 UNE EN ISO 5349-2 🇳🇱 NEN EN ISO 5349-2 🇩🇪 DIN EN ISO 6954 🇬🇧 BS EN ISO 6954 🇫🇷 NF EN ISO 6954 🇮🇹 UNI EN ISO 6954 🇪🇸 UNE EN ISO 6954 🇳🇱 NEN EN ISO 6954
1,591 Accredited labs
17 Countries

Showing 701–725 of 1,591 labs

DAkkS D-ML-13450-02-01 Würzburg, DE
Fazio-skapulo-humerale DSC2, DSG2, DSP, JUP, PKP2, TMEM43 ); SN Myopathie-Panel; SNV Myotone Dystrophie Typ 1 / M. Curschmann-Steinert (DMPK) + 3 more
View Profile
DAkkS D-ML-13355-03-00 Stuttgart, DE
Thrombozytenfunktion Antiepileptika: Benzodiazepine, Fentanyl Ethylglucuronid, Ethylsulfat Ciclosporin, Tacrolimus, Everolimus + 3 more
View Profile
DAkkS D-ML-13355-04-00 Stuttgart, DE
Zelldifferenzierung HLA Klasse I Antikörper Crossmatch (serologische Verträglichkeitsprobe im HLA-System) Serologische HLA-Klasse-I-Typisierung + 3 more
View Profile
DAkkS D-ML-13295-05-00 München, DE
HLA-Antikörpertestung (Detektion) HLA-Klasse I und II HLA-Antikörper (Spezifizierung) HLA-Antikörper Screening HLA-Antikörperdifferenzierung + 3 more
View Profile
DAkkS D-ML-13295-04-00 München, DE
Thromboplastinzeit) Thrombozytenfunktion 10-OH-Carbazepin 5-Hydroxyindolessigsäure (5-HIES) + 3 more
View Profile
DAkkS D-ML-13295-04-01 München, DE
Lamotrigin AFP HbA1c CA 125 AMH + 3 more
View Profile
DAkkS D-ML-13295-01-01 München, DE
Kleines Blutbild Differentialblutbild maschinell C-reaktives Protein (CRP) Differentialblutbild manuell Urinstatus + 3 more
View Profile
DAkkS D-ML-13295-03-00 München, DE
17-OH-Progesteron ACTH Androstendion Aldosteron Anti-TG Antikörper + 3 more
View Profile
DAkkS D-ML-13421-01-00 Ludwigshafen, DE
Liste aller Untersuchungsverfahren Webpräsenz des Medizinischen Laboratoriu CDT Ampicilin Cefepim + 3 more
View Profile
DAkkS D-ML-13136-01-01 Augsburg, DE
Rhythmusstörungen (ABCC9, AKAP9, ANK2,TT MSH2, MSH6, MUTYH, PMS2, PTEN, RAD51C, R Familiärer Brust- und Eierstockkrebs MSH2, MSH6, EPCAM ); SNV, CNV Birt-Hogg-Dubé-Syndrom (FLCN + 3 more
View Profile
DAkkS D-ML-13400-01-00 Groß Grönau, DE
AMA M2-3E IgG Anti-CCP (Cyclische Citrullin Antikörper) IgG Anti-dsDNS-NCX IgG Anti- Transglutaminase + 3 more
View Profile
DAkkS D-K-17518-01-01 Remscheid, DE
abweichungen Metrosoft CM und Messvolumen Metrosoft QUARTIS, mit einer Software der Fa. WENZEL Raumdiagonale Metromec Chur, CH von ≤ 4666 mm
View Profile
DAkkS D-K-15098-01-01 Leonberg, DE
Software von WENZEL einer Raumdiagonalen Messprojektoren einer Raumdiagonalen Koordinatenmessgeräte geräte mit einem Messmikroskope ≤ 600 mm Auswertesoftware Messvolumen mit + 2 more
View Profile
DAkkS D-PL-17382-02-00 München, DE
UIC-Mb 541-03 UIC-541-08 UIC-541-6 DIN 27205-9 DIN EN 15355 + 3 more
View Profile
DAkkS D-K-15077-01-00 Aschaffenburg, DE
Parallelendmaße 0,5 mm bis DIN EN ISO 3650:1999 Parallelendmaße aus 0,5 mm bis Keramik oder Wolframkarbid nach + 3 more
View Profile
DAkkS D-K-22877-01-01 Eschweiler, DE
(ein- und mehrgängige zylindrische Außen- und geradlinigen Flanken und symmetrischem Profil sowie positiven Flankenwinkeln) + 3 more
View Profile
UKAS 23015 Mansfield, GB
and Appendix 3 of HSG 227 (2004)) Appendix 5 of HSG 227 (2004))
View Profile
DAkkS D-PL-22819-01-00 Lüdenscheid, DE
DIN 40050-9 IEC 60068-2-2 IEC 60068-2-6 DIN EN IEC 60068-2-13 DIN EN 60068-2-14 + 3 more
View Profile
UKAS 7736 Chelmsford, GB
(HSG 248) – 2021 (PCM) based on HSG 248 SAS 02 based on HSG 248
View Profile

Kovia

Active
UKAS 9942 Royal William Yard, GB
Appendix 5 of HSG 227 (2004)) HSG 227 (2004) HSG 264 (2012) and Appendix 3 of
View Profile
DAkkS D-ML-13173-01-00 Bad Oeynhausen, DE
Thrombozytenfunktion Amiodaron/Desethylamiodaron Cotinin Cyclosporin A Everolimus + 3 more
View Profile
DAkkS D-ML-21357-01-00 Heppenheim, DE
Albumin Alkohol ALP Anti-Faktor Xa (Fragmin) AT3 + 3 more
View Profile
DAkkS D-PL-21175-01-01 Hasbergen, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3
View Profile
DAkkS D-PL-19181-01-00 Winnenden, DE
DIN 4150-1 DIN 4150-2 DIN 4150-3 DIN EN 13487 DIN 45635-46 + 2 more
View Profile
DAkkS D-K-15009-01-01 Leipzig, DE
Eindringkörper für 75° Sound system equipment — speech transmis Länge der Schnittlinien * Vergrößerungsnormale Abflachung bis 300 + 3 more
View Profile

No matching labs found.

Industries

Occupational health and safety Power tool and equipment manufacturing Construction and demolition Metalworking and mechanical industries Workplace risk assessment and hygiene services

Related Standards

  • ISO 5349-2 Mechanical vibration – Measurement and evaluation of human exposure to hand-transmitted vibration – Part 2: Practical guidance for measurement at the workplace
  • ISO 6954 Mechanical vibration – Criteria for the evaluation of vibration on machines with nominal powers above 15 kW
  • ISO 20643 Mechanical vibration – Hand-transmitted vibration – Apparatus and procedure for the laboratory measurement of vibration exposure from power drills and impact drills

Other Test Methods

0 labs selected