ISO 10816-3
Industrial Machine Vibration Assessment (>15 kW)
ISO 10816-3 specifies vibration evaluation criteria for industrial machines exceeding 15 kW output, measured on non-rotating structural parts at speeds between 120 and 15,000 r/min. This standard defines acceptance zones and diagnostic limits essential for commissioning and in-service monitoring of large industrial equipment. Plant operators, equipment manufacturers, and condition monitoring specialists rely on this test to detect developing mechanical faults and plan maintenance interventions. Accreditation guarantees standardised measurement practices that support production uptime and worker safety in industrial facilities across Europe.
What it measures
- Vibration velocity in mm/s (RMS) on bearing pedestals
- Measurement at specified speed ranges and operating conditions
- Zone classification (A: good, B: acceptable, C: just tolerable, D: unacceptable)
- Vertical and horizontal vibration components
- Trend analysis and transient response
🇩🇪
DIN EN ISO 10816-1
🇬🇧
BS EN ISO 10816-1
🇫🇷
NF EN ISO 10816-1
🇮🇹
UNI EN ISO 10816-1
🇪🇸
UNE EN ISO 10816-1
🇳🇱
NEN EN ISO 10816-1
🇩🇪
DIN EN ISO 20816-3
🇬🇧
BS EN ISO 20816-3
🇫🇷
NF EN ISO 20816-3
🇮🇹
UNI EN ISO 20816-3
🇪🇸
UNE EN ISO 20816-3
🇳🇱
NEN EN ISO 20816-3
1,591
Accredited labs
17
Countries
Showing 301–325 of 885 labs
Klinikum Nürnberg Institut für Klinische Chemie, Laboratoriumsmedizin und Transfusionsmedizin
Active
Antidepressiva 1:
Metabolit, Paroxetin, Fluvoxamin
Antidepressiva 2:
Antiepileptika:
Carbazepin, Sultiam, Lamotrigin
+ 3 more
Retikulozyten
Differentialblutbild
Erythrozytenzahl
Erythrozyten-Volumen (MCV)
Verteilungsbreite)
+ 3 more
Fazio-skapulo-humerale
DSC2, DSG2, DSP, JUP, PKP2, TMEM43 ); SN
Myopathie-Panel; SNV
Myotone Dystrophie Typ 1 / M.
Curschmann-Steinert (DMPK)
+ 3 more
Thrombozytenfunktion
Antiepileptika:
Benzodiazepine, Fentanyl
Ethylglucuronid, Ethylsulfat
Ciclosporin, Tacrolimus, Everolimus
+ 3 more
Zelldifferenzierung
HLA Klasse I Antikörper
Crossmatch (serologische
Verträglichkeitsprobe im HLA-System)
Serologische HLA-Klasse-I-Typisierung
+ 3 more
HLA-Antikörpertestung (Detektion)
HLA-Klasse I und II
HLA-Antikörper (Spezifizierung)
HLA-Antikörper Screening
HLA-Antikörperdifferenzierung
+ 3 more
Thromboplastinzeit)
Thrombozytenfunktion
10-OH-Carbazepin
5-Hydroxyindolessigsäure
(5-HIES)
+ 3 more
Klinikum der Ludwig-Maximilians-Universität München (LMU Klinikum) Institut für Laboratoriumsmedizin
Active
Lamotrigin
AFP
HbA1c
CA 125
AMH
+ 3 more
Kleines Blutbild
Differentialblutbild maschinell
C-reaktives Protein (CRP)
Differentialblutbild manuell
Urinstatus
+ 3 more
17-OH-Progesteron
ACTH
Androstendion
Aldosteron
Anti-TG Antikörper
+ 3 more
Liste aller Untersuchungsverfahren
Webpräsenz des Medizinischen Laboratoriu
CDT
Ampicilin
Cefepim
+ 3 more
Rhythmusstörungen (ABCC9, AKAP9, ANK2,TT
MSH2, MSH6, MUTYH, PMS2, PTEN, RAD51C, R
Familiärer Brust- und Eierstockkrebs
MSH2, MSH6, EPCAM ); SNV, CNV
Birt-Hogg-Dubé-Syndrom (FLCN
+ 3 more
AMA M2-3E IgG
Anti-CCP (Cyclische Citrullin
Antikörper) IgG
Anti-dsDNS-NCX IgG
Anti- Transglutaminase
+ 3 more
abweichungen
Metrosoft CM und Messvolumen
Metrosoft QUARTIS, mit einer
Software der Fa. WENZEL Raumdiagonale
Metromec Chur, CH von ≤ 4666 mm
Kneissl Messtechnik
Active
Software von WENZEL einer Raumdiagonalen
Messprojektoren einer Raumdiagonalen
Koordinatenmessgeräte geräte mit einem
Messmikroskope ≤ 600 mm
Auswertesoftware Messvolumen mit
+ 2 more
UIC-Mb 541-03
UIC-541-08
UIC-541-6
DIN 27205-9
DIN EN 15355
+ 3 more
Kolb & Baumann
Active
Parallelendmaße 0,5 mm bis
DIN EN ISO 3650:1999
Parallelendmaße aus 0,5 mm bis
Keramik oder
Wolframkarbid nach
+ 3 more
Kordt Messtechnik
Active
(ein- und mehrgängige
zylindrische Außen- und
geradlinigen Flanken und
symmetrischem Profil sowie
positiven Flankenwinkeln)
+ 3 more
Kostal Kontakt Systeme
Active
DIN 40050-9
IEC 60068-2-2
IEC 60068-2-6
DIN EN IEC 60068-2-13
DIN EN 60068-2-14
+ 3 more
Thrombozytenfunktion
Amiodaron/Desethylamiodaron
Cotinin
Cyclosporin A
Everolimus
+ 3 more
Albumin
Alkohol
ALP
Anti-Faktor Xa (Fragmin)
AT3
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN EN 13487
DIN 45635-46
+ 2 more
Eindringkörper für 75°
Sound system equipment — speech transmis
Länge der
Schnittlinien *
Vergrößerungsnormale Abflachung bis 300
+ 3 more
Durchfluss von Gasen 17 mL/s
transferstandards
Strömungswiderstand 5 mL/min
15,0 mL/min
Laminar Flow Elemente 17 mL/min
+ 3 more
No matching labs found.