EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
🇪🇸
UNE EN ISO 16810
🇳🇱
NEN EN ISO 16810
1,780
Accredited labs
17
Countries
Showing 1,151–1,175 of 1,780 labs
Navobi
Active
AM09 based on BS ISO 21527-1:
07L.1.11 based on ISO 5984:2002
DIN EN ISO 11290-2
ISO 4833-1
DIN EN ISO 8968-1
+ 3 more
Nemko S.p.A. a socio unico
Active
DIN EN 62368-1: 2016
DIN EN 61326-2-6
DIN EN 61010-2-101
EN IEC 62368-1
IEC 61326-2-6
+ 3 more
DIN EN ISO 7932
DIN EN ISO 6888-1
ISO 15213-1
DIN ISO 16649-2
DIN EN ISO 6888-3
+ 3 more
DIN EN ISO 15061 (D 34)
DIN EN 27888 (C 8)
DIN EN 1484 (H 3)
ISO 5667-21
DIN 38404-C 10
+ 3 more
Normec DETS
Active
BS 1377: Part 2: 1990
DIN EN 12457
No DETSC 5012 based on BS EN
staining based on HSG 248.
(HSG 248) – 2021
+ 1 more
Normec Hybeta
Active
DIN EN ISO 11737-2
DIN EN ISO 11607-2
DIN EN 868-5
DIN 58341
DIN EN ISO 15883-3
+ 3 more
Normec VRO
Active
#EN ISO 5164:14
# EN 116-97
NEN 4400-1
# ISO 13736
#ISO 6618
+ 3 more
Normec Valitech
Active
Tensile testing of metallic materials (I
positiver Überdruck -0,01 bar
Absolutdruck p
abs
Taupunkttemperatur
+ 3 more
Norsonic-Tippkemper
Active
Akustik
Übertragungsmaß von
Messmikrofonen
Messmikrofonen mit
Dämpfung eines
+ 3 more
North Star Environmental
Active
(HSG 248) – 2021
NSDOC 47 based on HSG 248
staining based on HSG 248.
(PCM) based on HSG 248
Not One Iota
Active
(HSG 248) – 2021
SOP-12, based on HSG 248
staining based on HSG 248
(PCM) based on HSG 248
Nuclear Restoration Services
Active
AIR KERMA RATE
AMBIENT DOSE
HBs-Antigen (Hepatitis B-Surface
RESPONSE:
PERSONEL DOSE
O.C. Consulting (UK)
Active
(HSG 264, 2012)
Appendix 5 of HSG 227 (2004)
(HSG 248) – 2021
(PCM) based on HSG 248
UNE-EN 14385
UNE-EN 15259
UNE-EN 13211
BS ISO 9096:2017
UNE 77216
+ 3 more
ONNEKEN Meß- und Prüftechnik
Active
Druck 0,03 bar
Absolutdruck Pabs
> -0,3 bar
> 3,0 bar
> −0,02 bar
+ 3 more
OPTOLUTION Messtechnik
Active
− Wärmezähler
Durchflusssensoren
als Teilgeräte von
Wärme- und
Kältezählern:
+ 3 more
Railway brake — magnetic track brakes (U
− Ebenheit
− Geradheit
− Winkelnormale
auch als Vor-Ort-Kalibrierung
+ 3 more
IEC 61400-23
ASTM G73 (2012)
IEC 60885-3, 2.4.1
IEC 60502-2
IEC 60840
+ 3 more
ISO 11819-1
(N 2 O) 0,000008
DIN EN ISO 16911-1
AG2 and IS EN 15259:2007
DIN EN 14790
+ 3 more
One Scientific
Active
ISO 6888-1
ISO 21528-2
BS ISO 4832:2006
ISO 4833-1
ISO 6579-1
+ 3 more
Optical Test & Calibration
Active
DC Resistance
DC CURRENT
DC VOLTAGE
DC RESISTANCE (cont’d)
No matching labs found.