EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
🇪🇸
UNE EN ISO 16810
🇳🇱
NEN EN ISO 16810
1,548
Accredited labs
15
Countries
Showing 1,526–1,548 of 1,548 labs
ifp-labs UK West Yorkshire
Active
on BS 4401:Part 3:1970(1986)
ISO 12966-1:2014 and
ISO 12966-4
CH 4026 based on BS 5766:Part
CH 4001 based on BS EN 12014-
+ 3 more
ift Rosenheim
Active
ASTM E 330/E 330M
ASTM E 283/E283M
DIN 4103-1
DIN 68706-1
UNE-EN 12211
+ 3 more
DIN EN ISO 5667-1 (A 4)
DIN ISO 5667-5 (A 14)
DIN EN ISO 5667-3 (A 21)
DIN EN ISO 19458 (K 19)
DIN 19643-1
+ 3 more
Taupunkttemperatur
fixpunktzellen
Railway braking — urban guided transport
Railway vehicle body structural requirem
SPRT-Sensor
+ 3 more
DIN EN 12681-1
DIN EN 12681-2
DIN EN ISO 5579
DIN EN 13068-3
DIN EN ISO 16371-2
+ 3 more
Absolutdruck p
abs
> 0,8 bar
> 1,2 bar
> 20 bar
+ 3 more
Absolutdruck p
Positiver Überdruck p e
Absolutdruck Pabs
> 0,8 bar
Überdruck p
+ 3 more
iocto
Active
Taupunkttemperatur
direktanzeigende −45 °C
Railway vehicle body structural requirem
Widerstandssensor
direktanzeigende > 200 °C
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten
+ 3 more
Basophile
Eosinophile
Erythrozyten
Hämatokrit
Leukozyten (Zellzahl)
+ 3 more
qbig
Active
Durchflussmess- 13 m³/h
- Hochspannungsmessgrößen
> 25 m³/h
Volumendurchfluss
> 40 m³/h
+ 3 more
Blutungszeit
5-Hydroxyindolessigsäure
Aminosäuren
Carbohydrate-Deficient-Transferrin
Everolimus
+ 3 more
tech-team Kalibrierlabor
Active
Gleichspannung 0,01 V
Messgeräte 0,33 V
3,3 V
330 V
Gleichstromstärke 30 µA
+ 3 more
velotech.de
Active
DIN EN ISO 4210-1
DIN EN 15194: 2018
DIN 33946
DIN EN 15918
DIN EN ISO 11243
+ 3 more
wbm Prüflabor
Active
DIN EN ISO 4136
DIN EN ISO 5178
DIN EN ISO 6892-2
DIN EN ISO 8496
DIN EN ISO 5173
+ 3 more
ISO 534
ISO 536
rs11887534
HABP2-Gen (c.1601G>A) rs7080536
ISO 1974
+ 3 more
Labor Wisplinghoff
Active
Liste aller Untersuchungsverfahren
Webpräsenz des Medizinischen Laboratoriu
Cannabinoide (Cannabinol, Cannabidiol)
Cannabinoide (THC)
Cannabinoide (THC-COOH)
+ 3 more
Überörtliche Berufsausübungsgemeinschaft Fachärzte für Laboratoriumsmedizin und Mikrobiologie
Active
Adrenalin
Amiodaron, Desmethylamiodaron
CDT
Amiodaron, Desethylamiodaron
Dopamin
+ 3 more
11-Desoxycortisol
Acylcarnitine
Agomelatin
Albendazolsulfoxid
a-Hydroxy-Alprazolam
+ 3 more
No matching labs found.