ISO 3746:2010
Sound Power Level — Survey Method
This test determines sound power levels of noise sources using an enveloping measurement surface and sound pressure level measurements. It is a survey-grade method suitable for field measurements of machinery, equipment, and industrial sources in moderately reflective environments. The method is widely used for noise compliance verification, product development, and environmental impact assessments. Accredited testing ensures consistent, defensible results for regulatory compliance and product labeling. This method bridges the gap between laboratory-grade precision and practical field measurements.
What it measures
- Sound power level (Lw) in decibels
- A-weighted and frequency-weighted sound power
- Directional sound power distribution
- Acoustic performance of noise sources
🇩🇪
DIN EN ISO 3744
🇬🇧
BS EN ISO 3744
🇫🇷
NF EN ISO 3744
🇮🇹
UNI EN ISO 3744
🇪🇸
UNE EN ISO 3744
🇳🇱
NEN EN ISO 3744
🇩🇪
DIN EN ISO 3745
🇬🇧
BS EN ISO 3745
🇫🇷
NF EN ISO 3745
🇮🇹
UNI EN ISO 3745
🇪🇸
UNE EN ISO 3745
🇳🇱
NEN EN ISO 3745
1,670
Accredited labs
18
Countries
Showing 1–25 of 834 labs
1A CAL
Active
- Gleichspannung
Josephson-Josephson
Multimeter
Quellen > 0,2 V
Spannungsnormale
+ 3 more
3-Rath Kalibrier+Prüftechnik
Active
Sound intensity — scanning method (ISO 9
Härteprüfmaschinen
Knoop- und
70 HR15N
42 HR30N
+ 3 more
3D Service
Active
Münchingen, D
CAM 2, Software von
Holos, Software von Carl
Metrologic, Software
von Metrologic Group ≤ 9090 mm
+ 3 more
8tree Scanner / 0 mm bis 100 mm
Laterale Größe von
Tiefenmaß/
-unterstand
(Härteskalen HV0,01
Kraft 0,5 N
Zug- und Druckkraft
Vibration measuring instruments — requir
Sound power — in-situ using reference so
20 kN
+ 3 more
Absolutdruck p
abs
positiver Überdruck
Positiver Überdruck p e
Überdruck p
+ 3 more
ABIT Ingenieure Trautmann
Active
DIN ISO 8297
DIN 45645-1
DIN 45645-2
DIN 45680 Beiblatt 1
ISO 11338-2
+ 2 more
ABIT Ingenieure Trautmann
Active
BS EN ISO 16283-1:2014+A1:2017BS EN ISO
ISO 10052
BS EN ISO 16283-2:2020
DIN EN ISO 16283-3
DIN 4109-4
AIP
Active
Railway brake — anti-slide device (UIC 5
Railway brake — magnetic track brakes (U
Railway brakes — conditions for homologa
Messgeräte im Kraftfahrwesen
− Abgasmessgeräte für Fremdzündungsmotor
+ 3 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847
IEC 61000-4-4: 2012
+ 3 more
AL-PRO
Active
IEC 61400-12-1 *
IEC 61400-12-5 *
IEC 61400-50 *
IEC 61400-50-1 *
IEC 61400-50-2 *
+ 1 more
ALAB-Analyse Labor in Berlin
Active
DIN ISO 16000-3
DIN ISO 16000-6
DIN EN ISO 16017-1
DIN ISO 12884
EN 16516
+ 3 more
ALS Germany
Active
DIN EN ISO 15587-1
DIN EN ISO 15587-2
DIN EN ISO 14403-2
DIN 38405-4
DIN 38405-8
+ 3 more
1,5 V/m bis 30 V/m
3 V/m bis 100 V/m
1 GHz bis 8
> 8 GHz bis 18
- Gleichspannung
+ 3 more
AQRAT
Active
Messschieber für 0 mm
Außen-, Innen- und > 500 mm
> 1000 mm
Tiefenmessschieber * 0 mm
Sondermessschieber 0 mm
+ 3 more
Taupunkttemperatur
Railway braking — urban guided transport
Temperaturtransmitter
Widerstandssensor *)
–30 °C
+ 3 more
Airbus Defence and Space
Active
- Gleichspannung
/ Messgeräte
1 µV
Quellen
> 1 V
+ 3 more
ISO 23351-1
ASTM E 1354
DIN EN ISO 717-1
DIN EN ISO 717-2
DIN EN ISO 3382-1
+ 3 more
Allgäuer Messzentrum
Active
Durchmesser 1 mm
510 mm
Rundheitsabweichung 1 mm
Parallelitätsabweichung
Rundheitsabweichung
+ 3 more
Cyclosporin A
Everolimus
FK 506 (Tacrolimus)
Sirolimus
6-Methylmercaptopurin
+ 3 more
No matching labs found.