IEC 62846
Railway Pantograph Interaction with Overhead Contact Line
This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.
What it measures
- Contact force between pantograph head and overhead line
- Arcing and electrical discontinuities during contact
- Pantograph head wear rate and material loss
- Dynamic lift and pressure stability at various speeds
- Compatibility with different catenary wire geometries
🇩🇪
DIN EN 50206
🇬🇧
BS EN 50206
🇫🇷
NF EN 50206
🇮🇹
UNI EN 50206
🇪🇸
UNE EN 50206
🇳🇱
NEN EN 50206
🇩🇪
DIN EN 50367
🇬🇧
BS EN 50367
🇫🇷
NF EN 50367
🇮🇹
UNI EN 50367
🇪🇸
UNE EN 50367
🇳🇱
NEN EN 50367
1,632
Accredited labs
19
Countries
Showing 201–225 of 875 labs
DIN 30655-1
DIN 30655-2
DIN 3590-1
DIN 3590-2
DIN 30652-2
+ 3 more
Anti-Müller-Hormon
Androstendion
CA 125
Cortisol
DHEA-S
+ 3 more
Azoospermie (AZF-Mikrodeletionen)
Fragiles X-Syndrom (FMR1)
Chorea Huntington (HTT)
Spinocerebelläre Ataxie Typ1
(ATXN1); Typ 2 (ATXN2); Typ 3
+ 3 more
HLA Klasse I Antikörper
lymphozytäre Antikörper
donorspezifische komplementabhängige
Gerinnungszentrum Rhein-Ruhr
Active
Thrombozytenaggregation
Epinephrin-Ristocetin) nach
Verschlusszeitbestimmung
Kollagen / ADP, PFA-Kollagen
Epinephrin, PFA-P2Y)
+ 3 more
Gesellschaft für Materialforschung und Prüfungsanstalt für das Bauwesen Leipzig mbH - MFPA Leipzig
Active
ISO 1920-4
DIN EN 480-11
DIN EN 12350-1
DIN EN 12350-3
DIN EN 12350-6
+ 3 more
Aktivator ADP / Epinephrin
Thrombozytenfunktionstest
Basophile Leukozyten, absolut
Basophile Leukozyten
Eosinophile Leukozyten
+ 3 more
Gigahertz Optik
Active
spektrale
Mikrofonempfindlichkeit
Photodioden
1 µA/W
Bestrahlungsstärke
+ 3 more
ASTM D3835-16
ASTM D6204-19a
ASTM D6601-19
ISO 11443
ASTM D1238-13
+ 3 more
ISO 3105
ASTM D 7042
ISO 2909
ASTM D 5293
ISO 3104
+ 3 more
HAZET-WERK Hermann Zerver
Active
Tensile testing of metallic materials (I
Vickers hardness test (ISO 6507)
Drehmoment 2 N·m
Handbetätigte
20 N·m
+ 3 more
Gleichspannung 10 mV
Messverstärker > 120 mV
> 12 V
> 120 V
Gleichstromstärke 10 µA
+ 3 more
Verschlusszeit (ADP, Epinephrin, P2Y12)
HCG, ß-HCG
PF4/Heparin-Komplexe
induzierte Thrombozytopenie, Test)
Differenzialblutbild (maschinell)
+ 3 more
HCG, ß-HCG
Ampicillin
Cefipim
Hämoglobin A1c (HbA1c)
Linecolid
+ 3 more
ADP-Antagonisten
TRAP-6-Aktivierung
ASS-Inhibition
Thrombozyten-Funktionsanalyse
β-HCG
+ 3 more
HENSOLDT Sensors
Active
- Gleichspannung
Spannungsmessgeräte
> 20 V
> 200 V
Spannungsquellen
+ 3 more
Natriumchlorid
Glucose
Kalium
Natrium
Albumin
+ 3 more
HFB Engineering
Active
DIN EN ISO 10666
DIN 53438-3
rs738409
DIN EN 1382
DIN EN 1383
+ 3 more
Gleichspannung a)
/ Messgeräte
> 600 kV
Messsysteme, Teiler
> 5 kV
+ 3 more
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-4: 2012
VDE 0847-4-4
IEC 61000-4-5: 2005
+ 3 more
HLK Stuttgart
Active
DIN EN 442-2
DIN EN 16430-1
DIN EN 16430-2
DIN EN 16430-3
DIN 4703-3
+ 3 more
HYDAC Systems & Services
Active
Gleichspannung 0 µV
Messgeräte > 20 mV
Messgeräte > 200 mV
> 2 V
> 20 V
+ 3 more
HaBu Hauck Prüftechnik
Active
Härte *) 20 HRA
Härtevergleichsplatten 20 HRB
nach Rockwell Verfahren 20 HRC
40 HRD
60 HRF
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
No matching labs found.