IEC 62846

Railway Pantograph Interaction with Overhead Contact Line

This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.

What it measures

  • Contact force between pantograph head and overhead line
  • Arcing and electrical discontinuities during contact
  • Pantograph head wear rate and material loss
  • Dynamic lift and pressure stability at various speeds
  • Compatibility with different catenary wire geometries
🇩🇪 DIN EN 50206 🇬🇧 BS EN 50206 🇫🇷 NF EN 50206 🇮🇹 UNI EN 50206 🇪🇸 UNE EN 50206 🇳🇱 NEN EN 50206 🇩🇪 DIN EN 50367 🇬🇧 BS EN 50367 🇫🇷 NF EN 50367 🇮🇹 UNI EN 50367 🇪🇸 UNE EN 50367 🇳🇱 NEN EN 50367
1,399 Accredited labs
17 Countries

Showing 226–250 of 1,399 labs

UKAS 0789 Great Dunmow, GB
Sound Calibrators FREQUENCY Microphones based: ½” & ¼” microphones @ 250 Hz + 3 more
View Profile
UKAS 1079 Gloucestershire, GB
BS ISO 488:2008, 2446:2008 and on BS 4401:Part 3:1970(1986) BS 696-2:1989 (superseded and BS ISO 6731:2010 ISO BS EN 3727-1:2002 + 3 more
View Profile
UKAS 4301 Llanishen, GB
Electrolytes in blood serum: Enzymes in blood serum: (Chlamydia pneumoniae, Mycoplasma urine: Hormones in blood serum: + 1 more
View Profile

Carl Zeiss

Active
DAkkS D-PL-12125-01-01 Oberkochen, DE
DIN EN 60601-1 IEC 60601-1 DIN EN 60601-1-1 IEC 60601-1-1 IEC 80601-2-77 + 3 more
View Profile
DAkkS D-K-21703-01-00 Oberkochen, DE
Carl Zeiss Industrielle ≤ 3818 mm Oberkochen, D 1) In den CMC sind die erweiterten Messu Carl Zeiss Industrielle ≤ 20 m Auswertesoftware Messvolumen mit + 3 more
View Profile
DAkkS D-K-15007-01-01 Oberkochen, DE
Parallelendmaße 50 mm DIN EN ISO 3650:1999 Thermischer Ausdeh- Maximale Dimension Bandbreite Höhe: 80 mm + 3 more
View Profile
DAkkS D-PL-12037-01-02 Jena, DE
DIN EN 61010-1 VDE 0411-1 IEC 61010-1 : 2010 DIN EN 60825-1 VDE 0837 + 3 more
View Profile
DAkkS D-K-12037-01-01 Jena, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 40 mm Parallelendmaße * ≥ 100 mm Strichmaßstäbe 0 mm + 3 more
View Profile
UKAS 27202 Paisley, GB
(HSG 264, 2012)
View Profile
UKAS 7914 Willsbridge, GB
5 of HSG 227 (2004)) (HSG 264, 2012)
View Profile
UKAS 1643 Chelmsford, GB
(cdt), Deletion an Pos 117 (HSG 248) – 2021 (PCM) based on HSG 248 BS 6068-4.12:1998 (withdrawn)
View Profile

CeGaT

Active
DAkkS D-ML-13206-01-01 Tübingen, DE
angeborener Chromosomensatz (Imbalancen im Genom, (Duplikationen/Del SNRPN-Region 15q11-13 UPD15 (UBE3A) SMN1; Spinale Muskelatrophie + 3 more
View Profile

Cenata

Active
DAkkS D-ML-21205-01-01 Tübingen, DE
Pränatales Screening auf Chromosomenstörungen (Trisomie 21, Trisomie 18, Trisomie 13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
View Profile
UKAS 0822 Southam, GB
Calibration of pressure Gas pressure (gauge) Gas Pressure (Differential) common mode pressure of 3.5 Hydraulic pressure (gauge) + 3 more
View Profile
DAkkS D-ML-13008-09-01 Berlin, DE
Whole genome sequencing (WGS: SNV, CNV/SV)
View Profile

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Chelab

Active
ACCREDIA 00051 Resana, IT
ISO 9308-1 ISO 7899-2 ISO 17410 ISO 16266 ISO 19250 + 3 more
View Profile
UKAS 6536 Leicester, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile
UKAS 9102 Bellshill, GB
(HSG 248) – 2021 SRV-002 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 0318 Derby, GB
Chronic progressive external Depth Internal Dial gauges and dial test Caliper + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
UKAS 0595 1 South Gyle Crescent, GB
simulation. parameters and ranges) digital and analogue
View Profile

Compli Group

Active
UKAS 4332 Poole, GB
DC CURRENT DC Resistance Oscilloscope Calibration DC VOLTAGE CAPACITANCE + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile

CoRFiLaC

Active
ACCREDIA 00285 Ragusa, IT
ISO 8968-1 DIN EN ISO 8968-1 ISO 3433:2008 DIN EN 14675 AOAC 991.14-1994 + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway infrastructure operators Public transport authorities Catenary system suppliers Rail maintenance and depot operators

Related Standards

  • EN 50206 Railway applications - Pantographs - Rules for testing and validation
  • EN 50367 Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead line
  • IEC 61853 Railway applications - Testing and measurement of pantograph and overhead line interaction

Other Test Methods

0 labs selected
Compare