IEC 62846

Railway Pantograph Interaction with Overhead Contact Line

This test evaluates the dynamic interaction between railway pantograph heads and overhead catenary contact lines to ensure reliable current collection and mechanical compatibility. It measures contact force stability, arcing behavior, and wear characteristics under various operational speeds and line configurations. The test is critical for main line and urban guided transport operators to prevent service disruptions, electrical failures, and premature wear. Accreditation ensures that laboratories can validate pantograph designs meet stringent European interoperability requirements and safety standards for both conventional and high-speed networks.

What it measures

  • Contact force between pantograph head and overhead line
  • Arcing and electrical discontinuities during contact
  • Pantograph head wear rate and material loss
  • Dynamic lift and pressure stability at various speeds
  • Compatibility with different catenary wire geometries
🇩🇪 DIN EN 50206 🇬🇧 BS EN 50206 🇫🇷 NF EN 50206 🇮🇹 UNI EN 50206 🇪🇸 UNE EN 50206 🇳🇱 NEN EN 50206 🇩🇪 DIN EN 50367 🇬🇧 BS EN 50367 🇫🇷 NF EN 50367 🇮🇹 UNI EN 50367 🇪🇸 UNE EN 50367 🇳🇱 NEN EN 50367
1,399 Accredited labs
17 Countries

Showing 276–300 of 1,399 labs

ENAC LC10.204 Fuenlabrada, ES
0 mV  U < 330 mV 330 mV  U < 3,3 V 3,3 0 mV  U < 120 mV 120 mV  U < 1,2 V 1,2 0 A  I  330 A 330 A < I  3,3 mA 3, 20 A  I  1025 A 20 A  I  1025 A F = 50 Hz + 3 more
View Profile
ENAC LE776 Madrid, ES
SM 5210 D UNE-EN ISO 27888 SM 5220 D SM 2130 B UNE-EN ISO 11885 + 3 more
View Profile
DAkkS D-ML-22411-01-00 Dresden, DE
Antikörper FILA-Klasse I Lymphozytäre Kreuzprobe E, -DRB1, -DQB1, -DPB1, DRB3/4/5, -DQA1, KIR MICA, MICB, CCR5832 + 3 more
View Profile
DAkkS D-ML-21979-01-00 Hamburg, DE
HLA-Typsierung (HLA-B*27) Azoospermiefaktor (AZFa/AZFb/AZFc) Chorea Huntington (HTT) OMIM# 143100 + 3 more
View Profile

DNKA

Active
UKAS 9730 Govan, GB
staining based on HSG 248. (PCM) based on HSG 248 (HSG 248) – 2021 QSOP 03 based on HSG 248 QSOP 01 based on HSG 248
View Profile
DAkkS D-K-11134-03-00 Kaiser-Wilhelm-Koog, DE
− Stromstärkeverhältnis - Gleichspannung / Messgeräte - Wechselspannung Gleichstromstärke > 100 µA + 3 more
View Profile

DRACE GEOCISA

Active
ENAC LE334 San Fernando de Henares, ES
EPA 9056 ISO 13167 SM 3120 B ISO 13166 UNE 73350-1
View Profile
DAkkS D-ML-17345-01-01 Frankfurt, DE
Faktor-V-Mangel (F5 inklusive Thrombozyten, PAC-1 Bindung CASQ2, KCNJ2, CALM2, CALM3, TECRL ) dbSNP r6027 ) Kardiomyopathie (PKP2, DSG2, SCN5A ) + 3 more
View Profile
DAkkS D-ML-17345-01-00 Frankfurt, DE
aller Untersuchungsverfahren im flexible Webpräsenz des Medizinischen Laboratoriu (VWF:CB) vWF-Multimere Erythrozyten + 3 more
View Profile
DAkkS D-ML-13219-01-01 Dresden, DE
CD34+ Stammzellen Erythrozyten Hämoglobin Leukozyten Bakterien- und Hefezellen + 3 more
View Profile
DAkkS D-ML-13219-01-00 Dresden, DE
Akkreditierungsbereich. Die Liste ist Erythrozyten Leukozyten Hämatokrit Thrombozyten + 3 more
View Profile
DAkkS D-ML-13461-01-01 Bad Kreuznach, DE
AB0-System Isoagglutinine (Serumeigenschaften) Rh-Merkmal D Rh-Untergruppen + 3 more
View Profile
DAkkS D-ML-13327-01-01 Hagen, DE
(Serumeigenschaften) Dithiothreithol-Behandlung Absorption oder Elution HNA (1a, 1b, 1c, 2a, 3a, Antikörperscree Liquorzelldifferenzierung + 3 more
View Profile
DAkkS D-K-20506-01-01 Aachen, DE
am Standort DSA Daten- und Systemtechnik Schreibendes Bremsmessgerät (HU-Adapter) Beschleunigung + 1 more
View Profile
DAkkS D-K-15152-01-01 Aalen, DE
- Gleichspannung > 0,01 V - Gleichstromstärke 0,1 mV/V > 2 mV/V + 3 more
View Profile
ENAC LC10.254 Sevilla, ES
50 ∙ 10-9 mol/mol ≤ C ≤ 237 · 10-9 mol/m 30∙ 10-9 mol/mol ≤ C ≤ 500 ∙ 10-9 mol/mo 50 ∙ 10-9 mol/mol ≤ C ≤ 1000 · 10-9 mol/ 50 ∙ 10-9 mol/mol ≤ C ≤ 237∙ 10-9 mol/mo 0,5 ∙ 10-9 mol/mol ≤ C ≤ 15 ∙ 10-9 mol/m + 1 more
View Profile
DAkkS D-PL-18858-01-02 Krefeld, DE
DIN EN ISO 11357-2 DIN EN ISO 11357-3 DIN EN ISO 3071 DIN 54278-1 ISO 11890-2 + 3 more
View Profile
DAkkS D-PL-14555-02-01 Karlsruhe, DE
ASTM D 3227 DIN 3500 EN 14350-2 DIN EN 12350-9 DIN 53512 + 3 more
View Profile
DAkkS D-PL-12098-01-01 Karlsruhe, DE
(SPG42), SPAST (SPG4), SPG11, SPG7, VAMP DIN EN 30-1-1 DIN EN 30-1-2 DIN 13013 DIN 13014 + 3 more
View Profile
UKAS 4303 Ammanford, GB
1) MS08P based on BS EN ISO MS02P based on BS EN ISO MS03P based on BS EN ISO MS06P based on BS EN ISO MF07P based on BS EN ISO + 3 more
View Profile
DAkkS D-K-23327-01-01 Bad Camberg, DE
Metrologic Group GmbH, nalen von: Wernau, D Neuss, D ≤ 1515 mm Wetzlar, D S.p.A., Turin, I + 3 more
View Profile
ACCREDIA 02012 Roma, IT
ETSI EN 319 412 ETSI EN 319 401 ETSI EN 319 411-2 ETSI EN 319 411-1
View Profile
DAkkS D-PL-17009-06-00 Wiesbaden, DE
DIN EN 60950-1 EN IEC 62368-1 DIN EN 60204-1 DIN EN 60825-1 DIN EN 61010-1 + 3 more
View Profile
DAkkS D-PL-17009-07-02 Köln, DE
IEC 60335-1: 2010 IEC 60335-2-29 DIN EN 60335-2-29 IEC 60335-2-65 DIN EN 60335-2-65 + 3 more
View Profile

BAU

Active
DAkkS D-PL-17009-09-01 München, DE
DIN 4420-1 DIN 4420-3 DIN EN 61347-1 ISO 12117-2 DIN 53449 + 3 more
View Profile

No matching labs found.

Industries

Railway rolling stock manufacturers Railway infrastructure operators Public transport authorities Catenary system suppliers Rail maintenance and depot operators

Related Standards

  • EN 50206 Railway applications - Pantographs - Rules for testing and validation
  • EN 50367 Railway applications - Current collection systems - Technical criteria for the interaction between pantograph and overhead line
  • IEC 61853 Railway applications - Testing and measurement of pantograph and overhead line interaction

Other Test Methods

0 labs selected