ISO 7626-2

Experimental Modal Analysis – Single-Point Excitation

ISO 7626-2 describes procedures for experimental modal analysis using single-point, single-axis excitation to characterise the dynamic properties and natural frequencies of structures and machines. This test method captures frequency response functions and mode shapes essential for structural design validation, vibration control, and fault diagnosis. Aerospace, automotive, civil engineering, and machinery manufacturers use modal analysis to refine designs and understand dynamic behaviour under operational loads. Accreditation ensures rigorous application of measurement protocols and data quality standards supporting engineering confidence in structural performance predictions.

What it measures

  • Frequency response functions (FRF) over specified frequency range
  • Natural frequencies (resonances) and modal damping ratios
  • Mode shapes and structural deflection patterns
  • Coherence and measurement quality indicators
  • Dynamic stiffness and impedance characteristics
🇩🇪 DIN EN ISO 7626-1 🇬🇧 BS EN ISO 7626-1 🇫🇷 NF EN ISO 7626-1 🇮🇹 UNI EN ISO 7626-1 🇪🇸 UNE EN ISO 7626-1 🇳🇱 NEN EN ISO 7626-1 🇩🇪 DIN EN ISO 7626-5 🇬🇧 BS EN ISO 7626-5 🇫🇷 NF EN ISO 7626-5 🇮🇹 UNI EN ISO 7626-5 🇪🇸 UNE EN ISO 7626-5 🇳🇱 NEN EN ISO 7626-5
1,591 Accredited labs
17 Countries

Showing 276–300 of 1,591 labs

DAkkS D-PL-12037-01-02 Jena, DE
DIN EN 61010-1 VDE 0411-1 IEC 61010-1 : 2010 DIN EN 60825-1 VDE 0837 + 3 more
View Profile
DAkkS D-K-12037-01-01 Jena, DE
Parallelendmaße * 0,5 mm DIN EN ISO 3650:1999 Parallelendmaße * 40 mm Parallelendmaße * ≥ 100 mm Strichmaßstäbe 0 mm + 3 more
View Profile
UKAS 27202 Paisley, GB
(HSG 264, 2012)
View Profile
UKAS 7914 Willsbridge, GB
5 of HSG 227 (2004)) (HSG 264, 2012)
View Profile
UKAS 1643 Chelmsford, GB
(cdt), Deletion an Pos 117 (HSG 248) – 2021 (PCM) based on HSG 248 BS 6068-4.12:1998 (withdrawn)
View Profile

CeGaT

Active
DAkkS D-ML-13206-01-01 Tübingen, DE
angeborener Chromosomensatz (Imbalancen im Genom, (Duplikationen/Del SNRPN-Region 15q11-13 UPD15 (UBE3A) SMN1; Spinale Muskelatrophie + 3 more
View Profile

Cenata

Active
DAkkS D-ML-21205-01-01 Tübingen, DE
Pränatales Screening auf Chromosomenstörungen (Trisomie 21, Trisomie 18, Trisomie 13, X0, XXX, XXY, XYY, XXYY, 22q11 (DiGe
View Profile
COFRAC 1-1970 Chateauneuf Sur Isere, FR
DIN EN 12207 DIN EN 12208 DIN EN 1026 DIN EN 12210 BS EN 14351-1:2006+A2:2016 + 3 more
View Profile

CevLab

Active
ACCREDIA 02206 Carpi, IT
DIN EN 60068-2-64 DIN EN-60068-2-6
View Profile
UKAS 0822 Southam, GB
Calibration of pressure Gas pressure (gauge) Gas Pressure (Differential) common mode pressure of 3.5 Hydraulic pressure (gauge) + 3 more
View Profile
DAkkS D-PL-20168-01-00 Jilin Province, CN
IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-14 IEC 60068-2-30 DIN EN 60068-2-30 + 3 more
View Profile
DAkkS D-ML-13008-09-01 Berlin, DE
Whole genome sequencing (WGS: SNV, CNV/SV)
View Profile

CheckImmune

Active
DAkkS D-ML-21360-01-00 Berlin, DE
Leukozytenzahl B-Zellzahl (Immunstatus Rezeptor-Besatz HLA-DR Leukozytensubpopulationen + 3 more
View Profile

Chelab

Active
ACCREDIA 00051 Resana, IT
ISO 9308-1 ISO 7899-2 ISO 17410 ISO 16266 ISO 19250 + 3 more
View Profile
UKAS 2613 Salisbury, GB
IEC 60068-2-2 BS 2011:2.1 Ca:1977 IEC 60068-2-30 MIL-STD 331B: 1994: DIN EN 60068-2-78 + 3 more
View Profile
UKAS 6536 Leicester, GB
(HSG 264, 2012) Appendix 5 of HSG 227 (2004))
View Profile
UKAS 9102 Bellshill, GB
(HSG 248) – 2021 SRV-002 based on HSG 248 (PCM) based on HSG 248
View Profile
UKAS 0318 Derby, GB
Chronic progressive external Depth Internal Dial gauges and dial test Caliper + 3 more
View Profile

Coesfeld

Active
DAkkS D-K-15093-01-00 Dortmund, DE
Kraft (WPM) Belastungseinrichtungen von Werkstoffprüfmaschinen Länge (WPM) 0,5 mm messeinrichtungen von + 3 more
View Profile
UKAS 0595 1 South Gyle Crescent, GB
simulation. parameters and ranges) digital and analogue
View Profile

Compli Group

Active
UKAS 4332 Poole, GB
DC CURRENT DC Resistance Oscilloscope Calibration DC VOLTAGE CAPACITANCE + 3 more
View Profile
DAkkS D-K-17132-01-00 Elsenfeld, DE
Messgeräte 0,001 V > 0,22 V > 2,2 V > 11 V > 22 V + 3 more
View Profile
UKAS 4092 Ipswich, GB
BS EN ISO 16283-1:2014+A1:2017BS EN ISO BS EN ISO 16283-2:2020 HTM 08-01 - 2013 BS EN ISO 140-4:1998 BS EN ISO 717-2:2020 + 3 more
View Profile
UKAS 4161 Leicester Forest East, GB
DIN EN 933-11 DIN EN 12390-3 DIN EN 933-3 DIN EN 12390-7 DIN EN 12697-5 + 3 more
View Profile
UKAS 0783 Duckmanton, GB
DC CURRENT LENGTH DC Resistance DC VOLTAGE Cold junction compensation + 3 more
View Profile

No matching labs found.

Industries

Aerospace and defence engineering Automotive design and validation Civil engineering and bridge design Heavy machinery and equipment development Vibration and noise control consulting

Related Standards

  • ISO 7626-1 Vibration and shock—Experimental determination of mechanical mobility—Part 1: Basic definitions and transducers
  • ISO 7626-5 Vibration and shock—Experimental determination of mechanical mobility—Part 5: Coupling of mechanical mobility measurement instrumentation
  • ISO 6954 Mechanical vibration and shock—Acceleration transducers—Specifications for laboratory standard instruments

Other Test Methods

0 labs selected
Compare