EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
🇪🇸
UNE EN ISO 16810
🇳🇱
NEN EN ISO 16810
1,780
Accredited labs
17
Countries
Showing 651–675 of 1,780 labs
HOP'LAB
Active
NF X43-050 (parties utiles de
NF X 43-050
NF X43-050 (parties utiles de la
HORIBA MIRA
Active
IEC/CISPR 25
DIN EN 55025: 2018
ISO 7637-2
ISO 11451-1
IEC/CISPR 12
+ 3 more
HSL Compliance
Active
(HSG 248) – 2021
M003 based on HSG 248
(PCM) based on HSG 248
M002based on HSG 248
HSG 227 (2004))
+ 2 more
DIN EN ISO 5579
DIN EN 12681-1
DIN EN ISO 17636-1
DIN EN ISO 20769-1
DIN EN ISO 20769-2
+ 3 more
HYDAC Systems & Services
Active
Gleichspannung 0 µV
Messgeräte > 20 mV
Messgeräte > 200 mV
> 2 V
> 20 V
+ 3 more
HaBu Hauck Prüftechnik
Active
Härte *) 20 HRA
Härtevergleichsplatten 20 HRB
nach Rockwell Verfahren 20 HRC
40 HRD
60 HRF
+ 3 more
Hampshire Scientific Service
Active
(HSG 248) - 2021
ASB/SOP/OM8 based on HSG 248
ASB/SOP/OM6 based on HSG 248
DIN EN 12697-11
on BS 4401:Part 3:1970(1986)
+ 3 more
Hartford Steam Boiler UK
Active
BS 2790 - Specification for the design a
BS 1113 - Specification for the design a
BS EN 13480 Parts 1 to 8 - Metallic
EN 13445 – Parts 1 to 10 Unfired pressur
BS EN ISO 15614 and ASME IX
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
(HSG 264, 2012)
and Appx. 3 of HSG 227 (2004))
Executive guides HSG 264 (2012)
Absolutdruck p
abs
> 41 bar
Negativer und
positiver Überdruck
+ 3 more
Heywood Williams Components
Active
DIN EN 1026
DIN EN 12046-2
BS 6375-1:2015 + A1:2016 and the
DIN EN 1027
DIN EN 1629
+ 3 more
Hohenstein Laboratories
Active
DIN 53160
DIN 54034
DIN 54056
DIN EN 20105-A02
DIN EN 20105-N01
+ 3 more
Taupunkttemperatur
thermometer, -80 °C bis
Railway braking — urban guided transport
> -35 °C bis
Temperatur- −35 °C bis
+ 3 more
Horiba Europe
Active
0,6 bar
ver Überdruck p e *
Absolutdruck p abs 100 mbar
> 70 mbar
Gaskonzentration
+ 3 more
Hottinger Brüel & Kjaer
Active
Übertragungsmaß von
Messmikrofonen oder
Freifeld-Leerlauf- 20 Hz
Freifeld -Übertragungsmaß
Vorverstärker, nach IEC
+ 3 more
DIN ISO 5667-5 (A 14)
DIN EN ISO 19458 (K 19)
DIN 19643-1
DIN EN ISO 7887 (C 1)
DIN 38404-C 4
+ 3 more
Hydrodata
Active
DIN EN ISO 5667-1 (A 4)
DIN 38402-A 12
DIN 38402-A 13
DIN 38402-A 15
DIN EN ISO 5667-3 (A 21)
+ 3 more
Hydrotechnik
Active
Negativer und
Positiver Überdruck p e
> 0,015 bar
Überdruck p
(ein- oder mehrgängige
+ 3 more
HygCen Germany
Active
DIN EN ISO 10993-1
DIN EN ISO 10993-5
DIN EN ISO 17405
ISO 10993-23
DIN EN ISO 10993-18
+ 3 more
Hygiene Nord
Active
DIN EN ISO 10993-5
DIN EN ISO 10993-1
DIN EN ISO 11737-2
DIN EN 1040
DIN EN IEC 60601-2-75
+ 3 more
Hygiene-Institut AYSID
Active
DIN 1946-4
DIN EN 13098
DIN EN ISO 17141
ISO 14644-3
DIN 12980
+ 1 more
Innen- und Tiefenmaße
Konventioneller
Wägewert/
Massenormale
Festkörpervolumen
+ 3 more
DIN EN ISO 16810
DIN EN ISO 16823
DIN EN ISO 16826
DIN EN ISO 16827
DIN EN ISO 17640
+ 3 more
No matching labs found.