EN ISO 17640
Ultrasonic Non-Destructive Testing
Ultrasonic testing (UT) detects internal flaws, wall thickness, and material discontinuities in metallic and composite components without damaging them. EN ISO 17640 covers manual UT of fusion-welded joints; phased-array (PAUT) and time-of-flight diffraction (TOFD) extend the technique to automated flaw sizing. UT is essential for pressure equipment, pipelines, and structural welds.
What it measures
- Internal flaw detection (cracks, inclusions, porosity)
- Flaw location, size, and orientation
- Wall thickness measurement
- Bond integrity in bonded structures
- Weld root and fusion defects
🇩🇪
DIN EN ISO 17640
🇬🇧
BS EN ISO 17640
🇫🇷
NF EN ISO 17640
🇮🇹
UNI EN ISO 17640
🇪🇸
UNE EN ISO 17640
🇳🇱
NEN EN ISO 17640
🇩🇪
DIN EN ISO 16810
🇬🇧
BS EN ISO 16810
🇫🇷
NF EN ISO 16810
🇮🇹
UNI EN ISO 16810
🇪🇸
UNE EN ISO 16810
🇳🇱
NEN EN ISO 16810
1,548
Accredited labs
15
Countries
Showing 626–650 of 1,548 labs
DIN EN ISO 5579
DIN EN ISO 17636-1
DIN EN 12681-1
DIN EN ISO 10893-6
DIN EN ISO 20769-1
+ 3 more
J B-Monitor
Active
(HSG 248) – 2021
No 1 based on HSG 248 – 2021
(PCM) based on HSG 248 – 2021
No 3 based on HSG 248 – 2021
(PCM) based on HSG 248
+ 1 more
JCS Technology
Active
ISO 178
BS 5350:Part C13
BS 2782 Part 10 Method 1005
BS EN ISO 14125
MIL-STD 810G:2008 Method 501.5
+ 3 more
DIN EN ISO 5579
DIN EN ISO 17636-1
DIN EN 12681-1
DIN EN ISO 17640
DIN EN ISO 16810
+ 3 more
UNE 320001
ISO/IEC 18045
ISO/IEC 15408
CEM ISO
ISO/IEC 24759
+ 2 more
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
elektronische Waagen
Innen- und Tiefenmaße
Konventioneller
+ 2 more
Javer Labs
Active
MIL-STD-810G, Method 508:7
BS 2011:2.1 Ca:1977
(IEC 60068-2-10:2005+A1:2018,
MIL-STD-810H, Method 508:8
Ebenheitsabweichung
verkörperungen z.B.
platten nach DIN 876:1984
Geradheitsabweichung
ebener Flächen, z.B.
+ 3 more
Johnson and Allen
Active
DC CURRENT
INSPECTION EQUIPMENT
AC CURRENT 50 Hz RMS
uncertainties may be increased.
Johs. Boss
Active
Außengewinde
Flankendurchmesser 3 mm bis 100 mm
0,5 mm bis 6 mm)
unsymmetrischem Profil
schiedlichen Ausgabeständen gestattet.
+ 3 more
MIL-PRF-46103E
DIN EN ISO 15106-3
DIN EN ISO 1522
DIN EN ISO 1523
ISO 16935:2007
+ 3 more
CD45 Percp+CD16+56+CD3
CD4
CD45 Percp+CD4+CD8
Adalimumab
Anti-Adalimumab Antikörper
+ 3 more
DIN EN ISO 5579
DIN EN ISO 17636-1
DIN EN 12681-1
DIN EN ISO 16809
DIN EN ISO 16810
+ 3 more
Jürgen Reindl ILB
Active
DIN EN ISO 17636
DIN EN 12681-1
DIN EN ISO 10893-6
DIN EN ISO 10675-1
DIN EN ISO 10675-2
+ 3 more
KB Prüftechnik
Active
Härteprüfmaschinen nach 100 HBW
Brinell- und
226 HBW
messeinrichtungen von
Härteprüfmaschinen
+ 3 more
KEMA
Active
IEC 60034
IEC 60034-2-1
IEC 60034-18-1
IEC 60034-4-1
IEC 60034-27-1
+ 3 more
KIMW Prüf- und Analyse
Active
ISO 21527-1
ISO 21527-2
ISO 37
DIN 53504
DIN EN 50178: 1998
+ 3 more
basophile, eosinophile, Granulozyten
Differenzialblutbild
Erythrozyten
Erythrozytenverteilungsbreite
(RDW)
+ 3 more
KRIWAN Testzentrum
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
KROMSCHROEDER
Active
Caudal m3/h 0,010 m3/h Q 250 m3/h 0,
Caudal m3/h 0,16 m3/h Q 2500 m3/h 0,
Kapraun Prüfdienst
Active
Railway brake — magnetic track brakes (U
− Ebenheit
− Geradheit
− Winkelnormale
auch als Vor-Ort-Kalibrierung
+ 3 more
IEH
Active
DIN EN 60034-15
VDE 0530-15
IEC 60034-15
DIN EN 60044-7
VDE 0414-44-7
+ 3 more
Luftkerma/-leistung
Dosis
Dosisleistung
Keighley Laboratories
Active
DIN EN IEC 60068-2-11
BS 3900:Pt F4
ASTM B 117
ASTM G85Appendix 5
ASTM G48 Method A
+ 3 more
No matching labs found.