EN 15302
Railway Wheelset Equivalent Conicity Measurement
This test method defines procedures for determining the equivalent conicity of railway wheelsets, a critical geometric parameter that affects vehicle stability, curving behavior, and wear characteristics. Equivalent conicity influences hunting oscillations, lateral forces, and noise generation during operation. The measurement is essential for railway manufacturers, maintainers, and operators to ensure safe and economical wheelset performance across different track geometries. Accreditation ensures consistent, reproducible measurements that support compliance with European interoperability standards and informed maintenance decisions.
What it measures
- Equivalent conicity value of wheelset profiles
- Wheel profile geometry and wear patterns
- Contact angle and friction coefficient relationships
- Stability margin and hunting potential
- Comparative conicity values for different operating conditions
🇩🇪
DIN EN 13715
🇬🇧
BS EN 13715
🇫🇷
NF EN 13715
🇮🇹
UNI EN 13715
🇪🇸
UNE EN 13715
🇳🇱
NEN EN 13715
🇩🇪
DIN EN 13296
🇬🇧
BS EN 13296
🇫🇷
NF EN 13296
🇮🇹
UNI EN 13296
🇪🇸
UNE EN 13296
🇳🇱
NEN EN 13296
1,632
Accredited labs
19
Countries
Showing 476–500 of 875 labs
WBC (Leukozyten)
RBC (Erythrocyten)
HGB (Hb)
HCT (Hk)
PLT (Thrombozyten)
+ 3 more
Chromosomensatz (angeboren)
Chromosomensatz (erworben)
Adrenogenitales Syndrom
Angelman-Syndrom (15q11-Region, UBE3A)
Mikrodeletionen; AZFa-c)
+ 3 more
HbA1c
Basophile, automatisch
Eosinophile, automatisch
Erythrozyten, automatisch
Leukozyten, automatisch
+ 3 more
HbA1c
Hämatokrit
Hämoglobin
Leukozyten
Thrombozyten
+ 3 more
HbA1c
Blutbild, groß (Blutbild klein
Hämoglobin, Hämatokrit, MCH, MCHC)
Retikulozyten
Thrombozyten
+ 3 more
Leukozyten
Erythrozyten
Thrombozyten
Hämatokrit
MCV
+ 3 more
Obligat anaerobe Bakterien
Grampositive aerobe und
anaerobe Kokken
Enterokokken
Mikrokokken
+ 3 more
automatische Zelldifferenzierung
Erythrozyten
Leukozyten
Retikulozyten
Thrombozyten
+ 3 more
Melutec Metrology
Active
Parallelendmaße * 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 100 mm
Messschieber für Außen-, 0 mm
+ 3 more
Metrolution
Active
Metrosoft CM, Software einer Raumdiagona
AG, Chur, CH ≤ 3333 mm
Oberkochen, D
GmbH, Wetzlar, D
AG, Chur, CH ≤ 7500 mm
Mettler-Toledo
Active
Flüssigkeitsvolumen *
Kolbenhubpipetten
Manuell betätigte
spritzen
Mehrfachdispenser
+ 3 more
MeßTechnikNord
Suspended
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
MeßTechnikNord
Active
- Gleichspannung
Messverstärker > 120 mV
> 1 V
> 12 V
> 1000 V
+ 3 more
Minebea Intec Bovenden
Active
Konventioneller
Wägewert/
Massenormale
Charpy impact test (ISO 148-1)
Salt spray / neutral salt fog test (ISO
+ 3 more
Bacillus cereus Toxin
Clostridium perfringens
Salmonella spp.
Shigella spp.
Staphylococcus aureus Toxin
+ 3 more
Mitutoyo Deutschland
Active
Parallelendmaße 0,5 mm
DIN EN ISO 3650:1999
Parallelendmaße
> 10 mm
Parallelendmaße > 100 mm
+ 3 more
Mobiler Kalibrierdienst Fini
Active
Gleichspannung 3 mV
Messgeräte 10 mV
> 100 mV
> 220 mV
> 11 V
+ 3 more
Temperatur 50 °C
Railway brake handbooks (UIC 547)
1) In den CMC sind die erweiterten Messu
IEC 61000-4-2: 2008
VDE 0847-4-2
IEC 61000-4-3: 2006
VDE 0847-4-3
IEC 61000-4-4: 2012
+ 3 more
Mühlenkreiskliniken AöR Institut für Laboratoriumsmedizin, Transfusionsmedizin und Mikrobiologie
Active
Differentialblutbild
Kleines Blutbild (maschinell)
Thrombozyten
Unreife Thrombozyten (IPF)
Urinsediment (maschinell)
+ 3 more
DIN 4150-1
DIN 4150-2
DIN 4150-3
DIN ISO 8297
DIN EN ISO 12354-4
+ 3 more
München Klinik gGmbH Medizet - Institut für Laboratoriumsmedizin und medizinische Mikrobiologie
Active
Hämoglobin A1c
Hämoglobin-Differenzierung
Erythrozyten
Basophile Granolozyten
Eosinophile Granulozyten
+ 3 more
NATEC Sensors
Active
Railway brakes — conditions for homologa
− Durchfluss von Flüssigkeiten
Gleichspannung U
(Simulation des Signals
generators)
+ 3 more
NEMKO
Active
IEC 61000-4-2: 2008
IEC 61000-4-3: 2006
IEC 61000-4-4: 2012
IEC 61000-4-5: 2005
IEC 61000-4-6: 2013
+ 3 more
Narda Safety Test Solutions
Active
Elektrische Feldstärke /
2 V/m
2,5 V/m
1 V/m
Magnetische Feldstärke /
+ 3 more
No matching labs found.